Nonsurgical removal of a knotted pulmonary artery catheter.

نویسندگان

  • B W Böttiger
  • H Schmidt
  • H Böhrer
چکیده

Though controversy exists regarding the utility of pulmonary artery catheters (PAC), their use persists in select patients. Knotting of these catheters upon insertion is a rare but serious complication. We present 2 cases of coagulopathic patients undergoing orthotopic liver transplantation complicated by PAC knotting on attempted line placement. Both knotted PAC were successfully removed nonsurgically in the operating room, allowing for timely continuation of the planned transplantations. It is essential for the clinician to recognize knotted PAC and understand strategies for safe removal.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Percutaneous removal of a knotted pulmonary artery catheter using a tracheostomy dilator

STATEMENT OF FINDINGS: This case report describes removal of a knotted, subclavian, pulmonary artery catheter using a tracheostomy dilator. With this simple method an invasive procedure might be averted.

متن کامل

Intraoperative removal of a knotted Swan-Ganz catheter during lung transplantation.

We describe the case of a 52-year-old man with end-stage emphysema who underwent a right-sided lung transplantation. During preoperative monitoring an apparently non-functioning Swan-Ganz catheter could not be removed through the insertion site - right internal jugular vein. Another Swan-Ganz catheter was successfully installed through the left internal jugular vein, pulmonary artery pressures ...

متن کامل

Removal of a knotted stimulating femoral nerve catheter using a saline bolus injection

OBJECTIVE Stimulating peripheral nerve catheters have become increasingly popular as part of postoperative multimodal analgesia for total knee arthroplasty. We describe a case of a successful nonsurgical removal of a knotted stimulating femoral nerve catheter after saline expansion of the catheter pocket at the bedside. CASE REPORT A 65-year-old female underwent total knee arthroplasty under ...

متن کامل

Occurrence and removal of a knotted pulmonary artery catheter: a case report.

The challenge of treating older, obese patients with various comorbidities has become a mainstay of anesthetic practice. In order to monitor and provide anesthesia safely, the nurse anesthetist must weigh the risks and benefits of all types of monitoring when these patients undergo major invasive procedures. One such option is the Swan-Ganz pulmonary artery catheter. During the last decade an e...

متن کامل

A technique for unknotting an intracardiac flow-directed balloon catheter.

Described is an unusual complication occurring during right-sided cardiac catheterization using a 7F flow-directed balloon catheter. During an attempt to direct the catheter from the main pulmonary artery into the pulmonary wedge position, the tip became entangled in a loop of catheter and knotted. Initially, all attempts to unknot or remove the catheter failed. A movable core guide wire was pa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of cardiothoracic and vascular anesthesia

دوره 5 6  شماره 

صفحات  -

تاریخ انتشار 1991