Unstable proximal extraarticular tibia fractures: a biomechanical evaluation of four methods of fixation.

نویسندگان

  • Richard D Peindl
  • Robert D Zura
  • Andrew Vincent
  • Edward R Coley
  • Michael J Bosse
  • Stephen H Sims
چکیده

OBJECTIVE To compare the biomechanical stability of extraarticular proximal tibia fractures reconstructed using a double-plate construct, locking plate system, hybrid external fixator, and single lateral periarticular plate, all from the same manufacturer. DESIGN Standardized proximal tibial fractures (AO classification 41-A3.2 and A3.3) in synthetic tibiae were stabilized using one of the four constructs. Load versus proximal fragment translation and rotation were monitored in each case. Fixation was evaluated for moderately unstable and completely unstable fractures simulated by wedge and gap osteotomies of the proximal femur. SETTING Academic medical center biomechanical engineering laboratory. MAIN OUTCOME MEASUREMENTS Proximal fragment axial displacement, varus rotation, and posterior rotation versus applied load for each of the constructs. RESULTS The double-plate construct was significantly stiffer than all other constructs with regard to resistance to axial displacement, varus rotation, and posterior rotation for both types of unstable fractures. With regard to axial stiffness, the double-plate construct was statistically similar to an intact tibia for moderately stable fractures. The locking plate and the external fixator were similar for stabilization of moderately unstable fractures, whereas the locking plate and the periarticular plate were significantly stiffer than the external fixator construct for completely unstable fractures. CONCLUSION For axial load applied to a wedge or gap osteotomy of the proximal tibia, the double-plate construct provided significantly more rigidity than the other constructs. The locking plate, periarticular plate, and hybrid external fixator tested provided similar rigidity for the wedge osteotomy, but for the gap osteotomy the external fixator could not support 600N without complete closure of the gap.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The use of combined 3.5 LCP unicortical plate and nail fixation in proximal tibia fractures and prevention of valgus and anterior angulation

Introduction: Intramedullary nailing (IMN) of high tibia fracture has some mechanical and biological advantages over the other form of fixation. However, valgus, apex anterior malalignment and anterior displacement of proximal fragment commonly occur after isolated IMN fixation of proximal high tibia fracture. The purpose of this study is to determine the effectiveness of using 3.5-mm locking c...

متن کامل

Challenges of Plate Fixation for Vancouver Type-C Fractures after a Well-Fixed Hip Arthroplasty Femoral Stem

The fixation of distal femoral fractures (Vancouver type-C fractures) following a well-fixed hip arthroplasty femoral stem has become a challenging issue for orthopedic surgeons due to the inter-prosthetic biomechanical effects such as negative, positive, and torsional strain. Surgeons have applied a range of constructs to overcome these difficulties. To minimize the risk of inter-prosthetic fr...

متن کامل

Biomechanical evaluation of a novel dualplate fixation method for proximal humeral fractures without medial support

BACKGROUND Comminuted fractures of the proximal humerus are generally treated with the locking plate system, and clinical results are satisfactory. However, unstable support of the medial column results in varus malunion and screw perforation. We designed a novel medial anatomical locking plate (MLP) to directly support the medial column. Theoretically, the combined application of locking plate...

متن کامل

Application of Additional Medial Plate in Treatment of Proximal Humeral Fractures With Unstable Medial Column

The purpose of this study was to use finite element analysis to compare the biomechanical characteristics after lateral locking plate (LLP) or LLP with a medial anatomical locking plate (LLP-MLP) fixation of proximal humeral fractures with an unstable medial column.First, a 3-dimensional, finite element analysis model was developed. Next, LLP and LLP-MLP implants were instrumented into the prox...

متن کامل

Union Following Biological and Rigid Fixations of Distal Tibia Extra-articular Fractures

Background: Distal tibia fractures are among the most common bony injuries, with a significant rate of nonunion anddelayed union. There are multiple methods for the management of distal tibia fractures. Among the plating methods,there are bridge plating and compression plating techniques. There is still a lack of evidence about whether one methodhas a higher rate of union than...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of orthopaedic trauma

دوره 18 8  شماره 

صفحات  -

تاریخ انتشار 2004