Rotary Ni-Ti profile systems for preparing curved canals in resin blocks: influence of operator on instrument breakage.
نویسندگان
چکیده
AIM The aim of this study was to determine the incidence of fracture of ProFile 0.4 and 0.6 taper Series 29 nickel-titanium instruments with respect to operator experience. METHODOLOGY A total of 125 simulated root canals in resin blocks with the same geometrical shape in terms of angle and radius of curvature and coronal and apical orifice diameter were used. Five operators prepared all the specimens using an identical step-down instrument sequence, each one preparing 25 canals. The operators included two endodontists and three general practitioners. Statistical data concerning the incidence of instrument failure was compiled using Statlab and Fisher's partial least square difference analysis of variance. RESULTS A total of 21 (16.8%) instruments fractured, all had 0.04 tapers. Nine size 25 instruments failed, 9 size 20 instruments failed and 3 size 15. During the study, the Binary Tree analysis of instrument failure revealed two operator populations belonging to two different study periods. The first period, which represented the first 13 root canal preparations, was called the 'learning period', and the second period, which represented the next 12 sample preparations, was called the 'application period'. A greater number of instruments failed during the first period than during the second. In the 'learning period', both groups of operators learned the same way. In the 'application period', two groups could be distinguished; the first group consisted of a general practitioner who produced worse results, and the second group consisted of the other four operators. CONCLUSIONS The results indicate the necessity of mastering this rotary canal preparation technique, and the importance of improving competence through learning and experience.
منابع مشابه
Relative efficacy of three Ni-Ti file systems used by undergraduates
The purpose of this study was to compare and evaluate the shaping ability of the three different Ni-Ti file systems used by undergraduate students. Fifty undergraduate students prepared 150 simulated curved root canals in resin blocks with three Ni-Ti file systems ProFile (PF), Manual ProTaper (MPT), Rotary ProTaper (RPT). Every student prepared 3 simulated root canals with each system respecti...
متن کاملComparison of the maintenance of root canal anatomy in severely curved resin blocks using RaCe and Flexmaster rotary systems
Comparison of the maintenance of root canal anatomy in severely curved resin blocks using RaCe and Flexmaster rotary systems Dr. S. Khedmat* - Dr. M. Vahdatifar** *- Associate Professor of Endodontics Dept. - Faculty of Dentistry – Tehran University of Medical Sciences. **- Endodontist. Background and Aim: Various rotary systems are available on the market, therefore selection of a proper instr...
متن کاملA comparison of transportation and time of canal preparation with stainless steel hand instruments and Ni-Ti rotary systems (In – Vitro)
A comparison of transportation and time of canal preparation with stainless steel hand instruments and Ni-Ti rotary systems (In – Vitro) Dr. MR. Sharifian* - Dr. MH. Nekoofar* - Dr. P. Motahari** - Dr. A. Tavakoli*** *-Assistant Professor of Endodontics Dept. – Faculty of Dentistry – Tehran University of Medical Sciences. **- Assistant Professor of Oral and Maxillofacial Pathology Dept. – Facul...
متن کاملمقایسه تأثیر سیستمهای چرخشی Profile و Race بر آناتومی اولیه کانالهای مشابهسازی شده دارای انحنای شدید
Background and Aim: Recent advances in technology have permitted manufacturers to produce endodontic files from NiTi alloy and rotary systems. According to manufacturers, these files maintain original canal shape better than hand files and reduce treatment time. The aim of this study was to compare a new rotary system (Race) with an older one (Profile) in maintaining the original shape of curve...
متن کاملA Comparative Study on the Shaping Ability of K3, Profile and Protaper Instruments in Simulated Curved Root Canals
INTRODUCTION The objective of this study was to compare the shaping ability of three rotary filing systems; constant taper K3 instruments, constant taper ProFile instruments and progressive taper ProTaper rotary instruments in clear resin blocks with simulated curved root canals. MATERIALS AND METHODS Forty five resin blocks were divided into three groups. Group A preparation was conducted wi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- International endodontic journal
دوره 32 6 شماره
صفحات -
تاریخ انتشار 1999