A microwave-assisted fluorescent labeling method for the separation and detection of amphetamine-like designer drugs by capillary electrophoresis.
نویسندگان
چکیده
A microwave-assisted fluorescence labeling method for use in CE-LIF (capillary electrophoresis-laser induced fluorescence) is described. Six amphetamine-like designer drugs, namely, o-, m-, p-chloro- and o-, m-, p-fluoro-amphetamine derivatives, were synthesized and used as model compounds. FITC (fluorescein isothiocyanate isomer I) and a blue-laser were used as the fluorescent labeling reagent and excitation source, respectively. When a microwave oven was used, the reaction was complete within ∼5 min, while the classical method required at least 20 h (usually, an overnight reaction). A mimic oral fluid sample was obtained by spiking oral fluid from a volunteer with the six standards, and after liquid-liquid extraction and microwave-derivatization, it was possible to process the analytes by CE-LIF within a period of ∼10 min; the wavelength of the blue-laser used was 473 nm. For comparison, data obtained using classical methods, including CZE-UV (capillary zone electrophoresis-UV absorbance detection), sweeping-MEKC-UV (micellar electrokinetic chromatography-UV absorbance detection) and LC-Q-TOFMS (liquid chromatography/electrospray ionization quadrupole time-of-flight mass spectrometry) are also reported.
منابع مشابه
Effect of Capillary Rinsing Protocol on the Reproducibility of Separation in Capillary Electrophoresis with Indirect UV Detection
Capillary electrophoresis (CE) with indirect UV detection is an interesting analytical method for the analysis of drugs and pharmaceuticals. Good and reproducible capillary quality is needed to develop robust methods and to facilitate method transfer in CE. It is widely accepted that preconditioning procedures are indispensable in capillary electrophoresis in order to achieve reproducibility of...
متن کاملEffect of Capillary Rinsing Protocol on the Reproducibility of Separation in Capillary Electrophoresis with Indirect UV Detection
Capillary electrophoresis (CE) with indirect UV detection is an interesting analytical method for the analysis of drugs and pharmaceuticals. Good and reproducible capillary quality is needed to develop robust methods and to facilitate method transfer in CE. It is widely accepted that preconditioning procedures are indispensable in capillary electrophoresis in order to achieve reproducibility of...
متن کاملChiral Separation of Basic and Zwitterionic Drugs by Highly Sulfated Cyclodextrins Using Short-End Injection Capillary Electrophoresis Highly Sulfated Cyclodextrins Using Short-End Injection Capillary Electrophoresis
Due to high resolution power of sulfated cyclodextrins (HS-CDs), utilization of these selectors for chiral resolution of 7 basic and 2 zwitterionic drugs have been examined. Experiments were performed on a HP3DCE instrument equipped with an on-column diode array UV absorbance detector. Fused silica capillaries with an inner diameter of 50 ?m, an outer diameter of 365 ?m, and a total length of 4...
متن کاملDetermination of herbicides and its metabolite in soil and water samples by capillary electrophoresis-laser induced fluorescence detection using microwave-assisted derivatization.
Methods were developed to determine glufosinate (GLUF), glyphosate (GLYP) and its metabolite, aminomethylphosphonic acid (AMPA) by capillary electrophoresis-laser induced fluorescence detection using 5-(4,6-dichlorotriazinylamino) fluorescein (DTAF) and fluorescein isothiocyanate (FITC) as the derivatizing reagents. To accelerate the labeling speed, a microwave-assisted derivatization method wa...
متن کاملChiral Separation of Basic and Zwitterionic Drugs by Highly Sulfated Cyclodextrins Using Short-End Injection Capillary Electrophoresis Highly Sulfated Cyclodextrins Using Short-End Injection Capillary Electrophoresis
Due to high resolution power of sulfated cyclodextrins (HS-CDs), utilization of these selectors for chiral resolution of 7 basic and 2 zwitterionic drugs have been examined. Experiments were performed on a HP3DCE instrument equipped with an on-column diode array UV absorbance detector. Fused silica capillaries with an inner diameter of 50 ?m, an outer diameter of 365 ?m, and a total length of 4...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Forensic science international
دوره 228 1-3 شماره
صفحات -