Corneal thickness, curvature, and elevation readings in normal corneas: combined Placido-Scheimpflug system versus combined Placido-scanning-slit system.

نویسندگان

  • Emmanuel Guilbert
  • Alain Saad
  • Alice Grise-Dulac
  • Damien Gatinel
چکیده

PURPOSE To evaluate agreement in central corneal thickness (CCT), keratometry, and anterior and posterior elevation map measurements in normal corneas between a combined Placido-Scheimpflug system and a combined Placido-scanning-slit elevation topography system. SETTING Department of Cataract & Refractive Surgery, Rothschild Foundation, Paris, France. DESIGN Evaluation of diagnostic test or technology. METHODS Measurements were performed with a combined Placido-Scheimpflug system (TMS-5) and a combined Placido-scanning-slit system (Orbscan II). Ultrasound (US) pachymetry was used as the reference for CCT measurements. Bland-Altman plots were used to evaluate agreement between instruments. RESULTS The mean CCT measurements by US pachymetry, the Placido-Scheimpflug system, and the Placido-scanning-slit system were 556.74 μm ± 42.45 (SD), 543.23 ± 36.73 μm, and 564.45 ± 41.26 μm, respectively. Although the CCT readings were statistically significantly thinner with the Placido-Scheimpflug system than with the other systems, there was high correlation between instruments. Peripheral corneal thickness readings were also thinner with the Placido-Scheimpflug system than with the Placido-scanning-slit system. Keratometry and anterior and posterior best-fit sphere (BFS) measurements were comparable between the 2 optical devices. Anterior and posterior maximum central elevations measured by the 2 instruments were not comparable or strongly correlated. Repeatability after 3 successive measurements was excellent for all parameters except maximum central elevation. CONCLUSIONS Although highly correlated, with corneal thickness readings were not interchangeable between the 2 optical devices. No statistically significant differences in keratometry or BFS measurements were observed between the 2 devices. There were important discrepancies in the maximum central elevation between the 2 topographers. FINANCIAL DISCLOSURE Drs. Gatinel and Saad are consultants to Technolas Perfect Vision. No other author has a financial or proprietary interest in any material or method mentioned.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Posterior corneal astigmatism.

In the optical system of the human eye, total refractive power consists mainly of corneal and lenticular components. Approximately two-thirds of the eye's converging power is at the air–cornea (tear film) interface; one-third is in the lens. Total corneal power is determined by corneal anterior and posterior curvature, corneal thickness, and the corneal refractive indices. Traditionally, anteri...

متن کامل

Clinical Correlation between Placido, Scheimpflug and LED Color Reflection Topographies in Imaging of a Scarred Cornea

This case report aims to evaluate safety, efficacy and feasibility of anterior surface imaging by a novel point-source reflection topographer, in comparison to four other corneal imaging modalities. A 17-year-old female patient, clinically diagnosed with chronic herpetic keratitis in her left eye was imaged by a novel multicolored-spot reflection topography system. We comparatively investigated...

متن کامل

Single session, intrauser repeatability of anterior chamber biometric and corneal pachy-volumetric parameters using a new Scheimpflug + Placido device

PURPOSE To analyze single session, intrauser reliability of a Scheimpflug device for anterior chamber (AC) and corneal parameters. METHODS In this observational study, 100 normal candidates underwent Scheimpflug analysis with Sirius 3D Rotating Scheimpflug Camera and Topography System (Costruzione Strumenti Oftalmici, Italy). Two scans in dark room conditions were performed by the same experi...

متن کامل

Topographic and tomographic properties of forme fruste keratoconus corneas.

PURPOSE To investigate the efficacy of topography and tomography indices combined in discriminant functions to detect mild ectatic corneas. METHODS The authors retrospectively reviewed the data of 143 eyes separated into three groups by the Corneal Navigator OPD scanning system (Nidek, Gamagori, Japan): normal (N; LASIK surgery with a 2-year follow-up; n = 72), forme fruste keratoconus (N top...

متن کامل

Forme Fruste Keratoconus Imaging and Validation via Novel Multi-Spot Reflection Topography

BACKGROUND/AIMS This case report aims to evaluate safety, efficacy and applicability of anterior surface imaging in a patient with forme fruste keratoconus (FFKC) based on a novel multi-spot, multicolor light-emitting-diode (LED) tear film-reflection imaging technology. CASE DESCRIPTION A 45-year-old male patient, clinically diagnosed with FFKC, with highly asymmetric manifestation between hi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cataract and refractive surgery

دوره 38 7  شماره 

صفحات  -

تاریخ انتشار 2012