preconcentration of trace amount Zn ( II ) using organic - solution - process able functionalized - grapheme

نویسنده

  • Ali Moghimi
چکیده

A novel and selective method for the fast determination of trace amounts of Zn(II)ions in water samples has been developed. The first organic-solution-processable functionalized-graphene (SPFGraphene) hybrid material with porphyrins. porphyrin–graphene nanohybrid, 5-4 (aminophenyl)-10, 15, 20-triphenyl porphyrin and its photophysical properties including optical (TPP) and grapheme oxide molecules covalently bonded together via an amide bond (TPPNHCO-SPFGraphene) were used as absorbent for extraction of Zn(II) ions by solid phase extraction method. The complexes were eluted with HNO3 (2M)10% V.V -1 mthanol in acetone and determined the analyte by flame atomic absorption spectrometry. The procedure is based on the selective formation of Zn(II) at optimum pH by elution with organic eluents and determination by flame atomic absorption spectrometry.The method is based on complex formation on the surface of the ENVI-18 DISK TM disks modified porphyrin–graphene nanohybrid, 5-4 (aminophenyl)-10, 15, 20-triphenyl porphyrin (TPP) and grapheme oxide molecules covalently bonded together via an amide bond (TPP-NHCO-SPFGraphene) followed * Correspondence should be addressed to Ali Moghimi, Department of Chemistry, Varamin (Pishva) Branch Islamic Azad University, Varamin, Iran. Email: [email protected]. Journal of science and today's world 2012, volume 1, issue 1, pages: 40-53 41 | P a g e by stripping of the retained species by minimum amounts of appropriate organic solvents. The elution is efficient and quantitative. The effect of potential interfering ions, pH, TPP-NHCOSPFGraphene, amount, stripping solvent, and sample flow rate were also investigated. Under the optimal experimental conditions, the break-through volume was found to about 1000mL providing a preconcentration factor of 600. The maximum capacity of the disks was found to be 398± 3 μg for Zn 2+ .The limit of detection of the proposed method is 5ng per 1000mL.The method was applied to the extraction and recovery of Zn in different water samples.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Preconcentration of Mo(II) on Micro Crystalline Modified with Functionalized-Nano Graphene

A organic-solution-processable functionalized-graphene (SPFGraphene) material has been studied on pre-concentration and determination of trace Mo(II)ions. In this process, the effects of pH solution, elution conditions on pre-concentration of trace Mo(II) were studied and the effect of interfering ions was also investigated. A selective method for the fast determination of trace amounts of Mo (...

متن کامل

Preconcentration of Mo(II) on Micro Crystalline Modified with Functionalized-Nano Graphene

A organic-solution-processable functionalized-graphene (SPFGraphene) material has been studied on pre-concentration and determination of trace Mo(II)ions. In this process, the effects of pH solution, elution conditions on pre-concentration of trace Mo(II) were studied and the effect of interfering ions was also investigated. A selective method for the fast determination of trace amounts of Mo (...

متن کامل

Solid phase extraction of trace cobalt (II) in industrial wastewaters by modified nanotube carbon carboxyl and its determination with flame atomic spectroscopy

Applying a simple and selective sample preparation procedure prior to instrumental analysis is the most important and crucial step in an analytical process. Up to now, various sample preparation techniques based on solid phase extraction (SPE) systems have been developed to isolate various types of analytes from different matrices. In the method presented for preconcentration and measurement of...

متن کامل

Solid phase extraction of trace cobalt (II) in industrial wastewaters by modified nanotube carbon carboxyl and its determination with flame atomic spectroscopy

Applying a simple and selective sample preparation procedure prior to instrumental analysis is the most important and crucial step in an analytical process. Up to now, various sample preparation techniques based on solid phase extraction (SPE) systems have been developed to isolate various types of analytes from different matrices. In the method presented for preconcentration and measurement of...

متن کامل

Fast Monitoring of the Phosphate Ions at Sub-mg L level with the Aim of Diamine-grafted MCM-41 Mesoporous silica and Ion Chromatography

In this work, an innovative method is described for the preconcentration of phosphate ions using ethylenediamine functionalized mesopor (MCM-41). Functionalized MCM-41 was synthesized and the presence of organic groups in the silica framework was demonstrated by FTIR spectrum. The amount of organic groups immobilized on silica surface was determined by elemental analysis and TGA. The functi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013