Loosening of the porous coating in total knee replacement.
نویسندگان
چکیده
We reviewed 40 cementless Porous Coated Anatomic knee replacements in 34 consecutive patients. The average follow-up was 12.9 months (range 6 to 36 months). At review, loose beads were identified in 23 knees, in 11 on the femoral side and in 16 on the tibial side (in five knees on both sides). One loose bead was adjacent to the patella. In four knees there were intra-articular beads. Radiolucent lines at the interface between bone and prosthesis were seen in 19 knees, in six on the femoral side and in 16 on the tibial side (in three knees on both sides). In relation to the tibial component loose beads were associated with a radiolucent line in all except one case. Progressive loosening with an increasing number of loose beads was seen in three knees. At this early stage of follow-up there was no correlation between the clinical results and the presence of loose beads.
منابع مشابه
Loosening of Total Knee Arthroplasty after Brucellosis Infection: A Case Report
In this report we describe a 78-year-old man whose total knee arthroplasty showed the symptoms of infection with brucella with radiographic signs of loosening 5 years after the index surgery. The patient was treated successfully after a 2-stage revision arthroplasty surgery along with using rifampicin and doxycycline for 8 weeks.
متن کاملDelamination of tantalum porous coating from a TKA due to regional dissemination of debris.
Metallic debris from metal-on-metal bearings is a recognized mode of failure that may lead to implant loosening and periprosthetic soft tissue reactions. The sequelae of metallosis have been most commonly reported with respect to total hip arthroplasty. The authors report a rare case of metallosis following a hybrid metal-on-polyethylene total knee arthroplasty that used a porous tantalum tibia...
متن کاملCementless fixation in total knee arthroplasty: down the boulevard of broken dreams - opposes.
In this study we present our experience with four generations of uncemented total knee arthroplasty (TKA) from Smith & Nephew: Tricon M, Tricon LS, Tricon II and Profix, focusing on the failure rates correlating with each design change. Beginning in 1984, 380 Tricon M, 435 Tricon LS, 305 Tricon 2 and 588 Profix were implanted by the senior author. The rate of revision for loosening ...
متن کاملHydroxyapatite-coated total knee replacement: clinical experience at 10 to 15 years.
This study describes 146 primary total knee replacements, either fully or partially coated with hydroxyapatite of which 74 knees in 68 patients were available for clinical and radiological assessment at a mean of 11.2 years (10 to 15). The global failure rate was 1.37% and survival rate with mechanical failure as the end-point was 98.14%. Radiological assessment indicated intimate contact betwe...
متن کاملIn-vivo study of osseointegration in Prestige LP cervical disc prosthesis
BACKGROUND A study was designed to quantify the extent of porous osseointegration at the prosthesis-bone interface in the Prestige LP prosthesis containing a plasma-sprayed titanium coating. METHODS Using an anterior surgical approach, cervical disc arthroplasty was performed in 8 mature male goats at the C3-C4 segment, followed by implantation of the Prestige LP prosthesis. The vertebral spe...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of bone and joint surgery. British volume
دوره 70 3 شماره
صفحات -
تاریخ انتشار 1988