The effects of ocular and lens parameters on the postlens tear thickness.

نویسندگان

  • Meng C Lin
  • Ying Q Chen
  • Kenneth A Polse
چکیده

PURPOSE To assess the effects of soft contact lens base curve radius (BCR), sex, ethnicity, central corneal curvatures, and vertical palpebral aperture size (PAS) on the postlens tear thickness (PLTT). METHODS The PLTT was measured using optical pachometry on 114 experienced lens wearers who were fitted with lathe-cut soft lenses (Alden 47, polymacon, 35.5% H2O, -2.00 diopter, and 14.0 mm). Each subject was randomly allocated to one lens group receiving a BCR of 7.9, 8.3, or 8.7 mm. Pachometry measurements were taken at 30 min after lens insertion. Vertical PAS and keratometry readings were measured for 94 of the 114 subjects. RESULTS The mean (95% confidence interval) PLTT was 15.7 microm (13.2-18.0 microm), 12.8 microm (10.9-14.7 microm), and 12.1 microm (10.2-14.0 microm) for the 7.9-mm, 8.3-mm, and 8.7-mm BCR groups, respectively. The differences in PLTT among the three BCR groups was significant (analysis of variance F-test; P=0.039). Post hoc testing using the Tukey honestly significant difference statistic showed that only the two extreme BCR groups (7.9 mm and 8.7 mm) were significantly different. Sex had no effect on the PLTT; however, the PLTT was significantly thinner for the Asian compared with non-Asian eyes (P=0.0001). The Asian PLTT did not vary with different soft lens BCRs. The non-Asian PLTT was thicker with lenses of the steep BCR compared with the flat BCR. CONCLUSION These results show that the base curve radius of a soft contact lens and several ocular characteristics can affect the thickness of the postlens tear film.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fenestrations enhance tear mixing under silicone-hydrogel contact lenses.

PURPOSE Extended wear of conventional hydrogel soft contact lenses (SCLs) is associated with adverse ocular responses. Some of these ocular events are thought to result from inadequate tear mixing in the postlens tear film (PoLTF). Therefore, strategies to increase tear mixing may improve the safety of extended-wear SCLs. Recently, it has been suggested that placing fenestrations in soft lenses...

متن کامل

Precorneal and pre- and postlens tear film thickness measured indirectly with optical coherence tomography.

PURPOSE To demonstrate the feasibility of indirectly measuring the precorneal tear film thickness and pre- and postlens tear film (PLTF) thickness using optical coherence tomography (OCT). METHODS Central corneal thickness (C(1)) which includes the tear film (T) of both eyes of 40 non-contact lens wearers was measured using OCT after calibration. The mean age of the 40 subjects was 31.2 +/- 9...

متن کامل

Comprehensive evaluation of dehydration impact on ocular tissue during Ramadan fasting

Purpose: The present study aimed to review the effect of dehydration during Ramadan fasting on the health and ocular parameters leading to changes in eye function. Methods: Articles included in the study were taken from Pub Med, Ovid, Web of Science and Google Scholar up to 2014.Related articles were also obtained from scientific journals in fasting and eye. Results: Dehydration and nutrition c...

متن کامل

Thickness of the pre- and post-contact lens tear film measured in vivo by interferometry.

PURPOSE To evaluate an interferometric method for measuring the thickness of the pre- (PLTF) and postlens tear film (POLTF) in subjects wearing hydrogel contact lenses. The precision and accuracy of measuring postlens tear thickness is compared with a previous method based on optical pachymetry and mechanical measurement of contact lens thickness. METHODS Reflectance spectra (562-1030 nm) fro...

متن کامل

The Biometric Values of Affected and Fellow Eyes in Patients with Acute Attack of Primary Angle Closure

Background: It has been estimated that 67 million people worldwide are affected with a primary glaucoma and that one-third have primary angle closure glaucoma. We aimed to determine the biometric differences between the eyes of patients with acute attack of primary angle closure and their non-involved fellow eyes. Methods: Twenty eight patients with acute attack of primary angle closure were re...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Eye & contact lens

دوره 29 1 Suppl  شماره 

صفحات  -

تاریخ انتشار 2003