Interaction between noise suppression and inhomogeneity correction in MRI
نویسندگان
چکیده
While cardiovascular disease is the leading cause of death in most developed countries, SPAMM-MRI can reduce morbidity by facilitating patient diagnosis. An image analysis method with a high degree of automation is essential for clinical adoption of SPAMM-MRI. The degree of this automation is dependent on the amount of thermal noise and surface coil-induced intensity inhomogeneity that can be removed from the images. An ideal noise suppression algorithm removes thermal noise yet retains or enhances the strength of the edges of salient structures. In this paper, we quantitatively compare and rank several noise suppression algorithms in images from both normal and diseased subjects using measures of the residual noise and edge strength and the statistical significance levels and confidence intervals of these measures. We also investigate the interrelationship between inhomogeneity correction and noise suppression algorithms and compare the effect of the ordering of these algorithms. The variance of thermal noise does not tend to change with position; however, inhomogeneity correction increases noise variance in deep thoracic regions. We quantify the degree to which an inhomogeneity estimate can improve noise suppression and whether noise suppression can facilitate the identification of homogeneous tissue regions, and thereby, assist in inhomogeneity correction.
منابع مشابه
SOM for intensity inhomogeneity correction in MRI
Given an appropriate imaging resolution, a common Magnetic Resonance Imaging (MRI) model assumes that object under study is composed of piecewise constant materials, so that MRI produces piecewise constant images. The intensity inhomogeneity (IIH) is modeled by a multiplicative inhomogeneity field. It is due to the spatial inhomogeneity in the excitatory Radio Frequency (RF) signal and other ef...
متن کاملروشی نوین در کاهش نوفه رایسین از مقدار بزرگی سیگنال دیفیوژن در تصویربرداری تشدید مغناطیسی (MRI)
The true MR signal intensity extracted from noisy MR magnitude images is biased with the Rician noise caused by noise rectification in the magnitude calculation for low intensity pixels. This noise is more problematic when a quantitative analysis is performed based on the magnitude images with low SNR(<3.0). In such cases, the received signal for both the real and imaginary components will fluc...
متن کاملNoise Estimation, Noise Reduction and Intensity Inhomogeneity Correction in MRI Images of the Brain
Noise Estimation, Noise Reduction and Intensity Inhomogeneity Correction in MRI Images of the Brain Michael Eziashi Osadebey, Ph.D. Concordia University, 2015 Rician noise and intensity inhomogeneity are two common types of image degradation that manifest in the acquisition of magnetic resonance imaging (MRI) system images of the brain. Many noise reduction and intensity inhomogeneity correctio...
متن کاملGeometric distortion correction in echo volumar imaging
Introduction: Echo volumar imaging (EVI) is a 3D extension of echo-planar imaging (EPI) that allows data from an entire volume to be acquired following a single excitation. However, only a few studies to date have applied EVI to functional MRI (fMRI) due to its high sensitivity to field-inhomogeneity induced distortions. In this study, we extend two EPI distortion correction techniques to EVI: ...
متن کاملReview of Intensity Inhomogeneity Correction Methods for Brain Mri Images
Intensity inhomogeneity is a smooth intensity change inside originally homogeneous regions. The intensity inhomogeneity degrades performance of image processing algorithms. Intensity inhomogeneity correction methods are important image processing algorithms which are used to reduce the inhomogeneity. Brain image intensity inhomogeneity correction is one of the most important parts of clinical d...