Highly Sensitive Gamma - Spectrometers of G ERDA for Material Screening : Part 2
نویسندگان
چکیده
The previous article about material screening for Gerda points out the importance of strict material screening and selection for radioimpurities as a key to meet the aspired background levels of the Gerda experiment. This is directly done using low-level gamma-spectroscopy. In order to provide sufficient selective power in the mBq/kg range and below, the employed gamma-spectrometers themselves have to meet strict material requirements, and make use of an elaborate shielding system. This article gives an account of the setup of two such spectrometers. Corrado is located in a depth of 15 m w.e. at the MPI-K in Heidelberg (Germany), Gempi III is situated at the Gran-Sasso underground laboratory at 3500 m w.e. (Italy). The latter one aims at detecting sample activities of the order ∼10 µBq/kg, which is the current state-of-the-art level. The applied techniques to meet the respective needs are discussed and demonstrated by experimental results.
منابع مشابه
Highly sensitive gamma - spectrometers of GERDA for material screening : Part I
The GERDA experiment aims to search for the neutrinoless double beta-decay of 76 Ge and possibly for other rare processes. The sensitivity of the first phase is envisioned to be more than one order of magnitude better than in previous 0νββ-decay experiments. This implies that materials with ultra-low radioactive contamination need to be used for the construction of the detector and its shieldin...
متن کاملDevelopment of antibody-based microarray assay for quantitative detection of aflatoxin B1
BACKGROUND: Aflatoxin B1 (AFB1) is a toxic metaboliteproduced by Aspergillus species that contaminates a wide range ofagricultural products. OBJECTIVES: This study was designed todevelop a rapid and highly sensitive immunoassay method inmicroarray format for quantitative detection of AFB1 to evaluatethe potential of microarray platform for high-throughput screening,which can be beneficial in fo...
متن کاملMeasurement of material uniformity using 3-D position sensitive CdZnTe gamma-ray spectrometers
We present results from two 1 cm3 CdZnTe gamma-ray spectrometers with full 3-D position sensitivity. To our knowledge, these are the "rst reported semiconductor spectrometers that provide independent spectral data for each of over 2000 volume elements. Energy resolutions of 1.5}1.6% FWHM and position resolutions of 0.7]0.7]0.5 mm were obtained at 662 keV gamma-ray energy from the central region...
متن کامل3D position sensitive CdZnTe gamma-ray spectrometers – improved performance with new ASICs
A 3-dimensional position sensitive CdZnTe gamma-ray spectrometer based on VAS3.1/TAT3 ASICs was developed and tested. The 3-D CZT spectrometer employs a 1.5 × 1.5 × 1 cm CdZnTe crystal with 11 by 11 pixelated anodes wire-bonded to the readout electronics. The signals from the anode pixels and the cathode were both read out through the ASICs. The pixel position provides the lateral 2-D coordinat...
متن کاملMicroscopic examination and elemental depth profiling analysis of lithium intercalated MnO 2 cathode using TEM and ERDA techniques
The objective of the proposed study is to use ANSTO’s transmission electron microscopy (TEM) and elastic recoil detection analysis (ERDA) combined with Rutherford back scattering (RBS). TEM and its associated techniques like HR-TEM (High resolution) and electron energy loss spectroscopy (EELS) are proposed to determine the lattice fringes and electron diffraction pattern with d-spacing correspo...
متن کامل