Fractional Flow Reserve, Absolute and Relative Coronary Blood Flow Velocity Reserve in Relation to the Results of Technetium-99m Sestambi Single-Photon Emission Computed Tomography in Patients With Two-Vessel Coronary Artery Disease

نویسندگان

  • Steven A. J. Chamuleau
  • Berthe L. F. van Eck-Smit
  • Angelina de Jong
چکیده

OBJECTIVES We sought to perform a direct comparison between perfusion scintigraphic results and intracoronary-derived hemodynamic variables (fractional flow reserve [FFR]; absolute and relative coronary flow velocity reserve [CFVR and rCFVR, respectively]) in patients with two-vessel disease. BACKGROUND There is limited information on the diagnostic accuracy of intracoronary-derived variables (CFVR, FFR and rCFVR) in patients with multivessel disease. METHODS Dipyridamole technetium-99m sestambi (MIBI) single-photon emission computed tomography (SPECT) was performed in 127 patients. The presence of reversible perfusion defects in the region of interest was determined. Within one week, angiography was performed; CFVR, rCFVR and FFR were determined in 161 coronary lesions after intracoronary administration of adenosine. The predictive value for the presence of reversible perfusion defects on MIBI SPECT of CFVR, rCFVR and FFR was evaluated by the area under the curve (AUC) of the receiver operating characteristics curves. RESULTS The mean percentage diameter stenosis was 57% (range 35% to 85%), as measured by quantitative coronary angiography. Using per-patient analysis, the AUCs for CFVR (0.70 6 0.052), rCFVR (0.72 6 0.051) and FFR (0.76 6 0.050) were not significantly different (p 5 NS). The percentages of agreement with the results of MIBI SPECT were 76%, 78% and 77% for CFVR, rCFVR and FFR, respectively. Per-lesion analysis, using all 161 measured lesions, yielded similar results. CONCLUSIONS The diagnostic accuracy of three intracoronary-derived hemodynamic variables, as compared with the results of perfusion scintigraphy, is similar in patients with two-vessel coronary artery disease. Cut-off values of 2.0 for CFVR, 0.65 for rCFVR and 0.75 for FFR can be used for clinical decision-making in this patient cohort. Discordant results were obtained in 23% of the cases that require prospective evaluation for appropriate patient management. (J Am Coll Cardiol 2001;37:1316–22) © 2001 by the American College of Cardiology

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Repair of all the components of the syndrome of aortic regurgitation and VSD.

Heyndrickx GR. Intracoronary and intravenous adenosine 50-triphosphate, adenosine, papaverine, and contrast medium to assess fractional flow reserve in humans. Circulation 2003;107:1877–1883. 21. Pijls N, van Son J, Kirkeeide R, De Bruyne B, Gould K. Experimental basis of determining maximum coronary, myocardial, and collateral blood flow by pressure measurements for assessing functional stenos...

متن کامل

Left Ventricular Dyssynchrony in Patients with Moderate Coronary Stenosis and Border Line Fractional Flow Reserve

The cutoff values of fractional flow reserve (FFR) to detect physiological myocardial ischemia are still controversial. Some studies have reported that left ventricular (LV) dyssynchrony occurs in patients with coronary artery disease (CAD). The purpose of this study was to investigate LV dyssynchrony in patients with moderate coronary stenosis and borderline FFR, using stress electrocardiograp...

متن کامل

Enhanced risk stratification with noninvasive measurement of coronary flow reserve using positron emission tomography.

Major progress has been made in the development and clinical application of dynamic imaging and tracer kinetic models to accurately measure absolute blood flow and coronary flow reserve (CFR) using quantitative positron emission tomography (PET) myocardial perfusion imaging (MPI) in patients with known or suspected coronary artery disease (CAD).1–6 Assessing CFR provides significantly greater s...

متن کامل

Diagnostic accuracy of stress myocardial perfusion imaging compared to invasive coronary angiography with fractional flow reserve meta-analysis.

BACKGROUND Hemodynamically significant coronary artery disease is an important indication for revascularization. Stress myocardial perfusion imaging is a noninvasive alternative to invasive fractional flow reserve for evaluating hemodynamically significant coronary artery disease. The aim was to determine the diagnostic accuracy of myocardial perfusion imaging by single-photon emission computed...

متن کامل

Myocardial blood flow assessment with 82rubidium-PET imaging in patients with left bundle branch block

OBJECTIVES Perfusion abnormalities are frequently seen in Single Photon Emission Computed Tomography (SPECT) when a left bundle branch block is present. A few studies have shown decreased coronary flow reserve in the left anterior descending territory, regardless of the presence of coronary artery disease. OBJECTIVE We sought to investigate rubidium-82 (82Rb) positron emission tomography imag...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016