Differences in quadriceps femoris muscle torque when using a clinical electrical stimulator versus a portable electrical stimulator.

نویسندگان

  • Christian L Lyons
  • Joel B Robb
  • James J Irrgang
  • G Kelley Fitzgerald
چکیده

BACKGROUND AND PURPOSE There have been conflicting views and evidence reported in the literature concerning differences in muscle torque-generating capacities between clinical ("plug-in") console devices whose power source is provided by an electrical outlet (60 Hz, alternating current-driven) and portable electrical muscle stimulators (smaller, battery-operated stimulators). The purpose of this study was to compare the torque-generating capacity of the quadriceps femoris muscle during neuromuscular electrical stimulation (NMES) between a clinical neuromuscular electrical stimulator (VersaStim 380) and a portable neuromuscular electrical stimulator (Empi 300PV). SUBJECTS Forty volunteer subjects with no known knee, neurological, or cardiovascular pathology (22 male, 18 female) participated in the study. METHODS All subjects were tested with the clinical and portable stimulators on 2 separate days. Peak isometric torque of the quadriceps femoris muscle was measured using a Biodex dynamometer. Peak isometric quadriceps femoris muscle torque achieved during NMES and the average quadriceps femoris muscle torque integral produced over 10 NMES contractions were measured for each stimulator. Subjects also rated the amount of pain they experienced during the 10 NMES contractions using a numeric pain scale. Paired t tests were used to compare mean differences in measured variables between stimulator conditions. RESULTS There were no differences in the peak torque or numeric pain ratings during the electrically stimulated contractions between stimulator conditions. The Empi 300PV produced a greater average torque integral compared with the VersaStim 380 during 10 electrically stimulated contractions (Empi 300PV=988.6-/+330.4 N.m-s, Versastim 380=822.7-/+292.6 N.m-s). DISCUSSION AND CONCLUSION The portable Empi 300PV stimulator produced comparable levels of average peak torque at comparable levels of discomfort to those produced by the VersaStim 380 clinical stimulator. The Empi 300PV maintained greater amounts of torque production during a 10-contraction training session compared with the VersaStim 380. Based on these data, we believe that the Empi 300PV has the potential to produce adequate levels of torque production for NMES quadriceps femoris muscle performance training. Further study is needed to determine the effectiveness of using the Empi 300PV for quadriceps femoris muscle performance training.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quadriceps femoris muscle torques and fatigue generated by neuromuscular electrical stimulation with three different waveforms.

BACKGROUND AND PURPOSE Neuromuscular electrical stimulation is used by physical therapists to improve muscle performance. Optimal forms of stimulation settings are yet to be determined, as are possible sex-related differences in responsiveness to electrical stimulation. The objectives of the study were: (1) to compare the ability of 3 different waveforms to generate isometric contractions of th...

متن کامل

Strength changes in the normal quadriceps femoris muscle as a result of electrical stimulation.

The purpose of this study was to examine the effectiveness of an electronic muscle stimulator in strengthening normal quadriceps femoris muscle without the assistance of simultaneous isometric muscle contraction. The sample consisted of 58 subjects who were randomly divided into three independent groups. One group (n = 19) served as controls; one group (n = 20) underwent daily stimulation of th...

متن کامل

Matching initial torque with different stimulation parameters influences skeletal muscle fatigue.

A fundamental barrier to using electrical stimulation in the clinical setting is an inability to maintain torque production secondary to muscle fatigue. Electrical stimulation parameters are manipulated to influence muscle torque production, and they may also influence fatigability during repetitive stimulation. Our purpose was to determine the response of the quadriceps femoris to three differ...

متن کامل

Noninvasive evaluation of electrical stimulation impacts on muscle hemodynamics via integrating diffuse optical spectroscopies with muscle stimulator.

Technologies currently available for the monitoring of electrical stimulation (ES) in promoting blood circulation and tissue oxygenation are limited. This study integrated a muscle stimulator with a diffuse correlation spectroscopy (DCS) flow-oximeter to noninvasively quantify muscle blood flow and oxygenation responses during ES. Ten healthy subjects were tested using the integrated system. Th...

متن کامل

Factors influencing quadriceps femoris muscle torque using transcutaneous neuromuscular electrical stimulation.

Quadriceps femoris muscle torque was measured in 40 subjects during transcutaneous neuromuscular electrical stimulation (NMES). Three different electrode types (carbonized rubber, sponge, and adhesive) were used on each subject, permitting determination of the factors that influenced the magnitude of quadriceps femoris muscle torque induced by NMES. This goal was accomplished by entering the va...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physical therapy

دوره 85 1  شماره 

صفحات  -

تاریخ انتشار 2005