Influence of graft size on spinal instability with anterior cervical plate fixation following in vitro flexion-distraction injuries.

نویسندگان

  • Reina Yao
  • Stewart D McLachlin
  • Parham Rasoulinejad
  • Kevin R Gurr
  • Fawaz Siddiqi
  • Cynthia E Dunning
  • Christopher S Bailey
چکیده

BACKGROUND CONTEXT Anterior cervical discectomy and fusion with plating (ACDFP) is commonly used for the treatment of distractive-flexion cervical spine injuries. Despite the prevalence of ACDFP, there is little biomechanical evidence for graft height selection in the unstable trauma scenario. PURPOSE This study aimed to investigate whether changes in graft height affect the kinematics of instrumented ACDFP C5-C6 motion segments in the context of varying degrees of simulated facet injuries. STUDY DESIGN In vitro cadaveric biomechanical study was used as study design. METHODS Seven C5-C6 motion segments were mounted in a custom spine simulator and taken through flexibility testing in axial rotation, lateral flexion, and flexion-extension. Specimens were first tested intact, followed by a standardized injury model (SIM) for a unilateral facet perch at C5-C6. The stability of the ACDFP approach was then examined with three graft heights (computed tomography-measured disc space height, disc space height undersized by 2.5 mm, and disc space height oversized by 2.5 mm) within three increasing unstable injuries (SIM, an added unilateral facet fracture, and a simulated bilateral facet dislocation injury). RESULTS In all motions, regardless of graft size, ACDFP reduced range of motion (ROM) from the SIM state. For flexion-extension, the oversized graft had a larger decrease in ROM compared with the other graft sizes (p<.05). Between graft sizes and injury states, there were a number of interactions in axial rotation and lateral flexion, where specifically in the most severe injury, the undersized graft had a larger decrease in ROM than the other two sizes (p<.05). CONCLUSIONS This study found that graft size did affect the kinematic stability of ACDFP in a series of distractive-flexion injuries; the undersized graft resulted in both facet overlap and locking of the uncovertebral joints leading to decreased ROM in lateral bending and axial rotation, whereas an oversized graft provided larger ROM decreases in flexion-extension. As such, a graft that engages the uncovertebral joint may be more advantageous in providing a rigid environment for fusion with ACDFP.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Distractable vertebral cages for reconstruction after cervical corpectomy.

STUDY DESIGN Retrospective study of 20 patients with degenerative cervical spinal canal stenosis who were treated with corpectomy followed by the placement of a distractable titanium cage (anterior distraction device [ADD]) (Ulrich GmbH & Co. KG, Ulm, Germany). OBJECTIVE To investigate the efficacy of distractable titanium cages for reconstruction following decompressive cervical corpectomy. ...

متن کامل

360° fixation with modern instrumentations of segment separation cervical spine injury in a 23-month-old.

In this case report clinical and technical lessons including seven years follow up learned from a flexion-distraction, highly unstable cervical spine injury causing a complete separation of C6-7 cervical segment with tetraparesis in a 23-month-old boy, are presented. To our knowledge this is the only documented case in medical literature where adult size implants (cage, plate and lateral mass s...

متن کامل

In vitro biomechanical evaluation of four fixation techniques for distractive–flexion injury stage 3 of the cervical spine

PURPOSE Anterior plate fixation has been reported to provide satisfactory results in cervical spine distractive flexion (DF) injuries stages 1 and 2, but will result in a substantial failure rate in more unstable stage 3 and above. The aim of this investigation was to determine the biomechanical properties of different fixation techniques in a DF-3 injury model where all structures responsible ...

متن کامل

The radiographic failure of single segment anterior cervical plate fixation in traumatic cervical flexion distraction injuries.

STUDY DESIGN A radiographic review of 87 patients with either unilateral or bilateral facet dislocations or fracture/dislocations treated with anterior cervical discectomy, fusion, and plating. OBJECTIVE The primary objective of this study was to report the incidence of radiographic failure and factors that would predispose to this loss of alignment. The secondary objective was to report the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The spine journal : official journal of the North American Spine Society

دوره 16 4  شماره 

صفحات  -

تاریخ انتشار 2016