Hydroxyapatite coated femoral stems in primary total hip arthroplasty: a meta-analysis.
نویسندگان
چکیده
We conducted meta-analysis of clinical studies of HA coated femoral stems in hip arthroplasty. After an exhaustive literature search, we abstracted relevant data on the outcomes of stem survival from aseptic loosening and Harris Hip scores. The risk ratios and mean differences with 95% confidence intervals (CI) are reported. 9 studies met our inclusion criteria for the analysis. The cumulative risk ratio for femoral stem survival from aseptic loosening was 1.0 (95% CI: 0.995 to 1.005) P = .98. The pooled mean difference for the Harris Hip scores (HHS) was 0.072 (95% CI: -0.062 to 0.206), P = .293. The results of this study demonstrate that there are no clinical benefits in the use of HA/porous coating over porous coating alone in primary hip arthroplasty.
منابع مشابه
The Effect of Hydroxyapatite Coating on Long-term Results of Total Hip Arthroplasty with Hydroxyapatite-coated Anatomic Femoral Stem
PURPOSE To evaluate the clinical and radiological results, as well as the survival rate, associated with total hip arthroplasty using a hydroxyapatite (HA)-coated anatomical femoral stem at a follow-up of ≥12 years. MATERIALS AND METHODS From April 1992 to May 1997, 86 patients (102 hips) underwent total hip arthroplasty with a HA-coated ABG I (Anatomical Benoist Giraud; Howmedica) hip prosth...
متن کاملHydroxyapatite-coated total hip arthroplasty: the impact on thigh pain and arthroplasty survival.
The purpose of this study was to evaluate the long-term clinical outcomes of primary total hip arthroplasty using an uncemented, hydroxyapatite-coated implant. We followed a consecutive series of 164 patients, who underwent total hip arthroplasty with the Furlong fully-hydroxyapatite coated implant over a mean time period of 12.8 years. Clinical and radiological analyses were performed. Roentge...
متن کاملBone density study of the proximal femur after hip arthroplasty with porous-coated implants
Progressive loss of bone mineral density around the femora! component of total hip replacement continues to pose a threat to long term prosthetic survival. A linear study was undertaken to measure bone mineral density on a monthly basis following total hip arthroplasty in 11 male patients. The opposite femur was used as the control measurement. Bone mineral density was unchanged at two mo...
متن کاملHydroxyapatite-coated femoral stems. Histology and histomorphometry around five components retrieved at post mortem.
We performed a histological and histomorphometric examination in five cadaver specimens of the femoral and acetabular components and the associated tissue which had been recovered between 3.3 and 6.2 years after primary total hip arthroplasty (THA) using a proximal hydroxyapatite (HA)-coated titanium alloy implant. All had functioned well during the patients' life. All the stems were fixed in t...
متن کاملEffects of hydroxyapatite coating on survival of an uncemented femoral stem
BACKGROUND AND PURPOSE Hydroxyapatite (HA) is widely used as a coating for uncemented total hip arthroplasty components. This has been suggested to improve implant ingrowth and long-term stability. However, the evidence behind the use of HA coating on femoral stems is ambiguous. We investigated survival of an uncemented, tapered titanium femoral stem that was available either with or without HA...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of arthroplasty
دوره 24 1 شماره
صفحات -
تاریخ انتشار 2009