Determination of the accuracy and optimal cut-off point for ELISA test in diagnosis of human brucellosis in Iran.
نویسندگان
چکیده
In endemic area the most challenging problem for brucellosis is to find a reliable diagnostic method. In this case-control study, we investigated the accuracy of ELISA test for diagnosis of human brucellosis and determined the optimal cut-off value for ELISA results in Iran. The laboratory diagnosis of brucellosis was performed by blood isolation of Brucella organism with a BACTEC 9240 system and/or detection of Brucella antibodies by standard agglutination test (titer ≥ 1:160). Serum level of ELISA IgG and ELISA IgM from 56 confirmed cases of brucellosis and 126 controls were compared with each other by Box plot graph and Receiver Operating Characteristic (ROC) curve. Box plot graphs showed the high degree of dispersion for IgG and IgM data in patients compared with all controls. We observed partially overlapping for IgM data (not for IgG) between cases and controls in graphs. The area under ROC curve for distinguishing between cases and controls was larger for IgG compared to IgM. Based on results of this study, ELISA IgG test was more reliable than ELISA IgM test in diagnosis of human brucellosis in Iran. Using a cut-off of 10 IU/ml and 50 IU/ml had most sensitivity (92.9%) and most specificity (100%) for ELISA IgG test, respectively.
منابع مشابه
ELISA Cut-off Point for the Diagnosis of Human Brucellosis; a Comparison with Serum Agglutination Test
Background: Brucellosis is a world-wide disease, which has a diverse clinical manifestation, and its diagnosis has to be proven by laboratory data. Serum agglutination test (SAT) is the most-widely used test for diagnosing brucellosis. The enzyme linked immunosorbent assay (ELISA) can also determine specific antibody classes against brucella. It is a sensitive, simple and rapid test, which coul...
متن کاملمحاسبه Cut-off point مناسب برای آزمون ELISA جهت تشخیص بروسلوز انسانی در ایران
Background: Finding a reliable diagnostic method for brucellosis is the most challengeable problem. In this study we determined the optimal diagnostic cut-off point for ELISA test.Methods: We gathered 56 confirmed cases of brucellosis. Furthermore blood samples from 126 controls including 73 healthy controls and 53 without brucellosis febrile patients were collected. In all of the cases and con...
متن کاملELISA Cut-off Point for the Diagnosis of Human Brucellosis; a Comparison with Serum Agglutination Test
BACKGROUND Brucellosis is a world-wide disease, which has a diverse clinical manifestation, and its diagnosis has to be proven by laboratory data. Serum agglutination test (SAT) is the most-widely used test for diagnosing brucellosis. The enzyme linked immunosorbent assay (ELISA) can also determine specific antibody classes against brucella. It is a sensitive, simple and rapid test, which could...
متن کاملAccuracy of Indirect ELISA Prepared from Recombinant Bp26 Gene of Brucella melitensis in Diagnosis of Human Brucellosis
Background: Considering the prevalence of brucellosis in Iran, it is necessary to choose a specific and sensitive laboratory method to diagnose it in a rapid and timely manner. The aim of this study was to assess the accuracy of indirect enzyme-linked immunosorbent assay (ELISA) for detecting brucellosis in humans in order to have an appropriate alternative to conventional tests such as Wright,...
متن کاملDetermination of sensitivity, specificity and cut off point of visual- Motor Bender Gestalt Test in the diagnosis of traumatic brain injury
Background: Bender Gestalt Test is one of the most famous neuropsychological tests, simple and easy to perform, and is used to evaluate brain injuries. This study aimed at determining the rate of sensitivity, characteristic and cut-off point of this test in patients with traumatic brain injury (TBI). Methods and Materials: Overall, 120 TBI patients with mean age of 31.25± 13.60 years old in...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Acta medica Iranica
دوره 51 10 شماره
صفحات -
تاریخ انتشار 2013