Feasibility of Using Pseudo-Continuous Arterial Spin Labeling Perfusion in a Geriatric Population at 1.5 Tesla.

نویسندگان

  • Sigurdur Sigurdsson
  • Lars Forsberg
  • Thor Aspelund
  • Rob J van der Geest
  • Mark A van Buchem
  • Lenore J Launer
  • Vilmundur Gudnason
  • Matthias J van Osch
چکیده

OBJECTIVES To evaluate the feasibility of using pseudo-continuous arterial spin labeling (pCASL) perfusion in a geriatric population at 1.5-Tesla. MATERIALS AND METHODS In 17 participants (mean age 78.8±1.63 years) we assessed; 1) inter-session repeatability and reliability of resting state perfusion in 27 brain regions; 2) brain activation using finger-tapping as a means to evaluate the ability to detect flow differences; 3) reliability by comparing cerebral blood flow (CBF) with pCASL to CBF with phase contrast (PC-MR). RESULTS The CBF (mean±standard deviation (SD)) for the whole brain grey matter (GM) was 40.6±8.4 and 41.4±8.7 ml/100g/min for the first and second scan respectively. The within-subject standard deviation (SDw), the repeatability index (RI) and intra-class correlation coefficient (ICC) across the 27 regions ranged from 1.1 to 7.9, 2.2 to 15.5 and 0.35 to 0.98 respectively. For whole brain GM the SDw, RI and ICC were 1.6, 3.2 and 0.96 respectively. The between-subject standard deviation (SDB) was larger than the SDw for all regions. Comparison of CBF at rest and activation on a voxel level showed significantly higher perfusion during finger tapping in the motor- and somatosensory regions. The mean CBF for whole brain GM was 40.6±8.4 ml/100g/min at rest and 42.6±8.6 ml/100g/min during activation. Finally the reliability of pCASL against the reference standard of PC-MR was high (ICC = 0.80). The mean CBF for whole brain measured with PC-MRI was 54.3±10.1 ml/100g/min and 38.3±7.8 ml/100g/min with pCASL. CONCLUSIONS The results demonstrate moderate to high levels of repeatability and reliability for most brain regions, comparable to what has been reported for younger populations. The performance of pCASL at 1.5-Tesla shows that region-specific perfusion measurements with this technique are feasible in studies of a geriatric population.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Practical Investigation of pseudo-Continuous Arterial Spin Labeling (pCASL) feasibility at very high field (11.75T)

Introduction: A new strategy for continuous arterial spin labeling (CASL) using pulsed RF and gradient fields and referred as pseudo-continuous ASL (pCASL), has recently been developed and optimized for human studies at 3T. Promising results demonstrated that pCASL combines advantages of pulsed ASL (PASL) and CASL by providing good labeling efficiency, high Signal to Noise (SNR) and multi-slice...

متن کامل

Reduced susceptibility effects in perfusion fMRI with single-shot spin-echo EPI acquisitions at 1.5 Tesla.

Arterial spin labeling (ASL) perfusion contrast is not based on susceptibility effects and can therefore be used to study brain function in regions of high static inhomogeneity. As a proof of concept, single-shot spin-echo echo-planar imaging (EPI) acquisition was carried out with a multislice continuous ASL (CASL) method at 1.5T. A bilateral finger tapping paradigm was used in the presence of ...

متن کامل

Single Coil Amplitude Modulated Continuous Arterial Spin Labeling Perfusion MR at 3.0 Tesla

J. Wang, Y. Zhang, R. L. Wolf, A. C. Roc, D. C. Alsop, J. A. Detre Department of Radiology, University of Pennsylvania, Philadelphia, PA, United States, Department of Neurology, University of Pennsylvania, Philadelphia, PA, United States, Department of Radiology, Harvard Medical School, Boston, MA, United States Introduction Recently technical developments demonstrated a greater than 2-fold SNR...

متن کامل

Multi-delay multi-parametric arterial spin-labeled perfusion MRI in acute ischemic stroke — Comparison with dynamic susceptibility contrast enhanced perfusion imaging☆

The purpose of the present study was to present a multi-delay multi-parametric pseudo-continuous arterial spin labeling (pCASL) protocol with background suppressed 3D GRASE (gradient and spin echo) readout for perfusion imaging in acute ischemic stroke. PCASL data at 4 post-labeling delay times (PLD = 1.5, 2, 2.5, 3 s) were acquired within 4.5 min in 24 patients (mean age 79.7 ± 11.4 years; 11 ...

متن کامل

Comparison of quantitative perfusion imaging using arterial spin labeling at 1.5 and 4.0 Tesla.

High-field arterial spin labeling (ASL) perfusion MRI is appealing because it provides not only increased signal-to-noise ratio (SNR), but also advantages in terms of labeling due to the increased relaxation time T(1) of labeled blood. In the present study, we provide a theoretical framework for the dependence of the ASL signal on the static field strength, followed by experimental validation i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • PloS one

دوره 10 12  شماره 

صفحات  -

تاریخ انتشار 2015