A Matlab-Simulink Approach To Shunt Active Power Filters

نویسندگان

  • George Adam
  • Alina G. Stan
  • Gheorghe Livint
چکیده

Due to the wide spread of power electronics equipment in modern electrical systems, the increase of the harmonics disturbance in the ac mains currents has became a major concern due to the adverse effects on all equipment. This paper presents the analysis and simulation using Matlab Simulink of a three-phase four wire neutral clamped active power filter (APF) compensating the harmonics and reactive power created by nonlinear balanced and unbalanced low power loads in steady state and in transients. The usefulness of the simulation approach to APF is demonstrated so APF designers have a better insight using Matlab Simulink in order to develop new APFs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Novel Reference Current Calculation Method for Shunt Active Power Filters using a Recursive Algebraic Approach

This paper presents a novel method to calculate the reference source current and the referencecompensating current for shunt active power filters (SAPFs). This method first calculates theamplitude and phase of the fundamental load current from a recursive algebraic approach blockbefore calculating the displacement power factor. Next, the amplitude of the reference mains currentis computed with ...

متن کامل

Comparison of Current Control Strategies for Three- level Four-leg Shunt Active Power Filter

This paper presents a comparison of two control strategies for 3-level 4-leg Shunt Active Power Filter (SAPF). The first method is based on hysteresis controllers. The second, proposed method is the Model Predictive Control (MPC) with a finite control-states set (FS) based on phase-to-phase model. The two methods are described and simulation results are presented and analyzed. Comparison is per...

متن کامل

Power quality improvement with a shunt active power filters using MATLAB / Simulink

Abstract: Along with the increasing demand on improving power quality i.e generally defined as any change in power (voltage, current, or frequency) that interferes with the normal operation of electrical equipment, the most popular technique that has been used is Active Power Filter (APF); This is because Passive filters performance is limited to a few harmonics and they can introduce resonance...

متن کامل

A Novel Approach in Design of a Fuzzy Based Shunt Active Power Filter for the Enhancement of Power Quality

Active power filters most of the times are employed for elimination of the harmonics created by non-linear loads in power system and for reactive power compensation of linear and non-linear loads. Compensating current is sent by shunt active power filter (SAF) at Point of Common Coupling (PCC) to mitigate current harmonics in the line. Hence sinusoidal nature of current and voltage waveforms ar...

متن کامل

Power Quality Improvement Using Matrix Converter Based UPQC

This paper proposes a matrix converter based unified power quality conditioner (MC–UPQC) for mitigating power quality problems. This proposed system is a combination of unified power quality conditioner and matrix converter. The UPQC is a combination of back-toback connected series and shunt active filters through a dclink. Voltage disturbances and harmonics are compensated by series active fil...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011