Replacing immunoassays for mephedrone, ketamines and six amphetamine-type stimulants with flow injection analysis tandem mass spectrometry.

نویسندگان

  • Ingrid A Lua
  • Shiou-Ling Lin
  • Huei R Lin
  • Ahai C Lua
چکیده

A screening procedure was developed for the simultaneous detection of mephedrone, six amphetamine-type stimulants (ATS), ketamine and its two metabolites with electrospray ionization flow injection analysis tandem mass spectrometry (FIA-MS-MS). Urine samples were fortified with deuterated analogues as internal standards, extracted with ethyl acetate and analyzed with FIA-MS-MS. The mass analyzer was operated in multiple reaction monitoring mode. Two product ions were monitored for each drug and internal standards. For each analyte, the limit of detection was less than 4 µg/L, within-day and between-day precisions (percent coefficient of variation) at three different concentrations were less than 7.3% and bias was between -17.3 and 11.8%. Total analysis time with FIA-MS-MS is 1.8 min per sample. A group of 215 urine samples were screened with immunoassay for ATS and analyzed with FIA-MS-MS and gas chromatography-mass spectrometry (GC-MS) for ketamines and ATS. The analysis of ATS by immunoassay and GC-MS was 96.7% concordant. The analysis of three ketamines and seven ATS by FIA-MS-MS and GC-MS was 97.2% concordant. The FIA-MS-MS procedure is efficient, accurate, flexible and capable of detecting analytes of different chemical groups. It can replace immunoassays for the screening of new designer drugs when commercial immunoassays are unavailable.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of amphetamine-type stimulants (ATSs) and synthetic cathinones in urine using solid phase micro-extraction fibre tips and gas chromatography-mass spectrometry

In recent years, an increasing number of stimulant drugs and new psychoactive substances (NPSs) have caused concern in scientific communities and therefore innovative methods to extract compounds from complex biological samples are required. This work is aimed at developing and validating a clean, convenient and straightforward extraction procedure with microliter amounts of organic solvent usi...

متن کامل

Using cheminformatics to predict cross reactivity of “designer drugs” to their currently available immunoassays

BACKGROUND A challenge for drug of abuse testing is presented by 'designer drugs', compounds typically discovered by modifications of existing clinical drug classes such as amphetamines and cannabinoids. Drug of abuse screening immunoassays directed at amphetamine or methamphetamine only detect a small subset of designer amphetamine-like drugs, and those immunoassays designed for tetrahydrocann...

متن کامل

Screening of stimulants including designer drugs in urine using a liquid chromatography tandem mass spectrometry system.

A rapid, reproducible and sensitive reversed phase liquid chromatography-mass spectrometry method was developed and validated for the identification and semi-quantitative confirmation of stimulants in urine. The method is capable of separating compounds such as cocaine and metabolites, amphetamines, substituted cathinones and other designer drugs, with a total run time of 11 min. The method was...

متن کامل

Trends of Amphetamine Type Stimulants DTR Mass Load in Poznan Based on Wastewater Analysis

BACKGROUND The aim of this study was to determine the monthly DTR mass load of amphetamine-type compounds in Poland as well as an investigation of cyclical behaviour by using time series analysis and especially trends analysis. METHODS Amphetamine, methamphetamine and MDMA (ecstasy) were detected in wastewater samples collected from the main Wastewater Treatment Plant in the city of Poznan us...

متن کامل

Liquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization

A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of analytical toxicology

دوره 36 8  شماره 

صفحات  -

تاریخ انتشار 2012