To investigate if the surface modification of intraocular lens (IOL) is efficient in the prevention of posterior capsular opacification (PCO), the acrylic surface of intraocular lens (Acrysof) was polymerized with polyethylene glycol (PEG-IOL). The human lens epithelial cells (1 x 10(4) cells/mL) were inoculated on PEG grafted or unmodified acrylic lenses for the control. The adherent cells on each IOL surface were trypsinized and counted. The every PEG-IOL was implanted in 20 New Zealand rabbits after removal of crystalline lens. The formations of PCO were checked serially through retroilluminated digital photography, and the severity scores were calculated using POCOman. The cell adherence patterns on each IOL were examined by scanning electron microscopy. As a result, the mean number of adherent cells of PEG-IOL (3.2+/-1.1 x 10(3)) tended to be smaller than that of the acrylic controls (3.6+/-1.9 x 10(3)) without a statistical significance (p=0.73). However, the mean severity of PCO formation in PEG-IOL was significantly lower than that in the control during the third to sixth weeks after surgery. Scanning electron microscopy revealed that the more patch-like cells were found firmly attached to the IOL surface in control than in the PEG-IOL. Conclusively, PEG polymerization to the acrylic IOL would possibly lessen the formation of PCO after cataract removal.
منابع مشابه
Clinical properties of a novel, glistening-free, single-piece, hydrophobic acrylic IOL
A new, single-piece, hydrophobic acrylic lens - the first constructed with a lens optic and haptics comprised of a hydroxyethyl methacrylate-polyethylene glycol phenyl ether acrylate-styrene copolymer, cross-linked with ethylene glycol dimethacrylate, and labeled as "glistening-free" - was recently introduced globally. Glistenings have been a significant source of clinical concern with previous...
متن کاملRefractive Error and Anterior Segment Parametric Changes in Patients with Posterior Capsular Opacification after Nd: YAG Laser Posterior Capsulotomy
Background and Objective: Cataract is one of the most common causes of blindness in the world, and posterior capsular opacification (PCO) is the most common complication after cataract surgery. Nd: YAG laser posterior capsulotomy is a standard method for the treatment of PCO. The aim of this study was to investigate the effects of Yas laser capsulotomy on anterior segment parameters and lenticu...
متن کاملImprovement of Uveal and Capsular Biocompatibility of Hydrophobic Acrylic Intraocular Lens by Surface Grafting with 2-Methacryloyloxyethyl Phosphorylcholine-Methacrylic Acid Copolymer
Biocompatibility of intraocular lens (IOL) is critical to vision reconstruction after cataract surgery. Foldable hydrophobic acrylic IOL is vulnerable to the adhesion of extracellular matrix proteins and cells, leading to increased incidence of postoperative inflammation and capsule opacification. To increase IOL biocompatibility, we synthesized a hydrophilic copolymer P(MPC-MAA) and grafted th...
متن کاملNeodymium: Yag Laser Capsulotomy Rates Following Implantation of Silicone and Acrylic Intraocular Lenses
Received for publication January’ 2009 ... ........................... Purpose. The objective of this study is to compare the frequency of Neodymium YAG laser capsulotomy in eyes receiving silicon foldable posterior chamber intraocular lenses with those receiving acrylic foldable posterior chamber intraocular lenses. Material and Methods. This Comparative study was carried out at Ophthalmology ...
متن کاملComparison of clinical results between heparin surface modified hydrophilic acrylic and hydrophobic acrylic intraocular lens.
PURPOSE To compare the clinical results of heparin surface modified (HSM) hydrophilic acrylic intraocular lens (IOL) with those of hydrophobic acrylic IOL. METHODS One hundred patients with cataract were randomized to receive one of acrylic foldable IOLs after phacoemulsification: HSM hydrophilic acrylic IOL (n=50) BioVue3 (BioVue, OII, Ontario, CA, USA) and hydrophobic acrylic IOL (n=50) Sen...
متن کامل