Intrastromal corneal ring segment implantation with the femtosecond laser in a post-keratoplasty patient with recurrent keratoconus.

نویسندگان

  • Efekan Coskunseven
  • George D Kymionis
  • Haluk Talu
  • Ebru Aslan
  • Vasilios F Diakonis
  • Dimitrios I Bouzoukis
  • Ioannis Pallikaris
چکیده

A 50-year-old woman had implantation of intrastromal corneal ring segments for recurrent keratoconus 15 years after penetrating keratoplasty. Two segments (0.15 mm and 0.25 mm) were inserted without any intraoperative or postoperative complications, using the femtosecond laser to create the tunnels (superior and inferior). Ten months after the procedure, the uncorrected visual acuity was 20/100, compared with counting fingers preoperatively, and the best spectacle-corrected visual acuity improved from 20/63 to 20/32. Although the results are encouraging, the long-term effect of this approach for the management of post-keratoplasty patients with recurrent keratoconus is not known.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Single intrastromal corneal ring segment implantation using the femtosecond laser after radial keratotomy in a keratoconic patient.

A 33-year-old woman with irregular astigmatism 6 years after radial keratotomy (RK) for keratoconus was treated with implantation of a single intrastromal corneal ring segment (Keraring) using the femtosecond laser. The segment (0.150 mm thick with a 160-degree arc) was inserted in the steepest area (inferior) with no intraoperative or postoperative complications. Six months postoperatively, th...

متن کامل

Complications of intrastromal corneal ring segment implantation using a femtosecond laser for channel creation: a survey of 850 eyes with keratoconus.

PURPOSE To report complications after the implantation of intrastromal corneal ring segments (Keraring; Mediphacos, Belo Horizonte, Brazil) in keratoconic eyes using a femtosecond laser (IntraLase; Advanced Medical Optics, Santa Ana, California, USA) for channel creation. METHODS Retrospective chart review of 531 patients (850 eyes) who underwent Keraring insertion using a femtosecond laser f...

متن کامل

Intrastromal corneal ring segment implantation by femtosecond laser for keratoconus correction.

PURPOSE To report the outcomes after the implantation of intrastromal corneal ring segments (KERARING) aided by femtosecond laser for the correction of keratoconus. DESIGN Prospective consecutive interventional study. PARTICIPANTS Twenty-one eyes of 16 consecutive keratoconic patients with mean age 32+/-10.2 years. Forty-five percent were keratoconus grade I, 20% grade II, 15% grade III, an...

متن کامل

Predictability of Tunnel Depth for Intrastromal Corneal Ring Segments Implantation Between Manual and Femtosecond Laser Techniques.

PURPOSE To compare the predictability of intrastromal tunnel depth creation for intrastromal corneal ring segments (ICRS) implantation between manual dissection and femtosecond laser using a high-resolution anterior segment optical coherence tomography (AS-OCT). METHODS This multicenter study included patients with keratoconus who had Ferrara-type ICRS implantation at Hospital de Braga using ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cataract and refractive surgery

دوره 33 10  شماره 

صفحات  -

تاریخ انتشار 2007