Evaluation of a benchtop capillary gas chromatograph-mass spectrometer for clinical toxicology.
نویسندگان
چکیده
We evaluated the Hewlett-Packard 5995B benchtop capillary gas chromatograph-mass spectrometer (GC-MS) for its ability to identify drugs commonly detected and (or) measured in the clinical toxicology laboratory. Initial experiments indicated that the instrument as originally configured, with an isolation valve between the gas chromatograph and mass spectrometer, was unsatisfactory for the identification of hypnotics-sedatives. However, with the capillary inserted directly into the ion source, we could detect 10 ng of these drugs on a total-ion chromatogram. The software programs cause the instrument to be highly automated. In terms of ease of operation and speed it was found suitable for use in a routine clinical laboratory. Chromatography of urine extracts on the capillary gas chromatograph-mass spectrometer yielded excellent resolution of parent compounds and metabolites (e.g., diphenhydramine together with approximately four metabolites and propoxyphene with four metabolites). However, the manufacturer's computer program used to evaluate the quality of the match between the experimental mass spectra and the 375 drug reference spectra was only moderately successful in identifying unknown compounds. The ability of this capillary GC-MS to identify most compounds with a high degree of confidence will be increased by enlarging the library to include more drugs and metabolites and by using a more reliable computerized matching program.
منابع مشابه
Determination of serum cholesterol by isotope dilution mass spectrometry with a benchtop capillary gas chromatograph/mass spectrometer: comparison with the National Reference System's Definitive and Reference Methods.
We developed an isotope dilution mass spectrometric cholesterol method with [25,26,27-13C]cholesterol as internal standard and a benchtop gas chromatograph/mass spectrometer (GC/MS) that is much easier and less time consuming than previously described Reference and Definitive Methods for cholesterol. The internal standard, cholesterol standards, and unknown specimen are delivered volumetrically...
متن کاملClinical applications of gas chromatograph/mass spectrometer/computer systems.
Gas chromatograph/mass spectrometer/computer systems can be used to quantify a wide variety of compounds of clinical interest. A quadrupole instrument operated in the chemical ionization (Cl) mode was used in these studies. Because of the sensitivity and specificity of selective ion detection, it is possible to make measurements routinely in the nanogram to picogram range, with 0.1-1.0 ml sampl...
متن کاملVolatile carboxylic acid profiling in physiological fluids: direct injection into a gas chromatograph/mass spectrometer.
We present a procedure for the profiling of the volatile carboxylic acids and neutral compounds in blood or urine using the direct injection of the acidified sample into a gas chromatograph interfaced with a mass spectrometer by a jet separator. The non-volatile components remain at the head of the SP-1000 column while the volatile components move through the column. Up to sixty physiological s...
متن کاملEnhanced Essential Oils Analysis Using a High Performance Benchtop GC/MS System Application Note
A gas chromatograph (GC) coupled with a mass spectrometer (MS) forms a powerful tool for high quality quantitative and qualitative analysis. However, GC/MS analysis of complex mixtures such as essential oils often is a time-consuming task due to limitations in techniques and instrumentation. Faster analyses of these mixtures are possible by coupling the 5973A mass selective detector (MSD) with ...
متن کاملTandem Gas Chromatography - Mass Spectrometry Analysis of Volatiles From Soybean Oil
A time vs. volatile decomposition studY was made on commercially available soYbean oil aaed d • '" un er normal laboratory room conditions. Samples were taken at weekly intervals for peroxide v.alue (PV) determinations, organoleptic evaluatIOns and volatile analyses. Volatiles, stripped from the oil samples in an all-glass system devoid of connecting joints, were collected and sealed in attache...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 31 5 شماره
صفحات -
تاریخ انتشار 1985