BACKGROUND The PAS-Port (Cardica Inc, Redwood City, CA) is an automated system that allows for the clampless anastomosis of vein grafts to the aorta. The intent of this study was to prospectively compare one year graft patency of this system with conventional hand-sewn anastomoses in a prospective, randomized trial. METHODS A total of 99 patients undergoing elective off-pump coronary bypass surgery were randomized to receive their proximal anastomoses with either the hand-sewn conventional technique or with the PAS-Port system. Patient follow-up consisted of multislice computed tomographic scans performed at discharge and one year postoperatively. RESULTS Three patients had to be converted to on-pump due to technical reasons. Fifty-one patients were randomly assigned to the PAS-Port group and 48 patients to the control group. In five patients in the control group severe atherosclerosis of the aorta required cross-over to the use of the PAS-Port device, and in one patient in the PAS-Port group conversion to a hand-sewn anastomosis. Sequential anastomoses were performed in 88% of the control group and 73% of PAS-Port group grafts. Time needed for completion of the proximal anastomosis including graft loading was 187 +/- 19 seconds for the PAS-Port group and 406 +/- 34 seconds for the control group (p < 0.001). One patient died unrelated to cardiac events due to septic multiorgan failure and one stroke was observed in the control group. There was a trend toward a lower rate of postoperative delirium in the PAS-Port group (11.7% vs 25%, p = 0.088). Patency at discharge (100% PAS-Port group vs 97.8% control group) and after one year (97.8% PAS-Port group vs 93.7% control group) were comparable. One patient of the PAS-Port group died during long-term follow-up as a result of a severe stroke due to cerebrovascular disease. CONCLUSIONS This prospective randomized study demonstrated excellent short and midterm patency in both the hand-sewn and PAS-Port grafts. The PAS-Port system allowed for the rapid, safe, and effective creation of a proximal anastomosis without the need to clamp the aorta. Based on this study we consider this product a valid alternative for proximal anastomosis, especially in patients with severe aortic disease, to avoid side clamping of the aorta.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the PAS-Port Proximal Anastomosis System in coronary artery bypass surgery (the EPIC trial).

OBJECTIVE During coronary surgery, proximal vein graft anastomoses have been performed by using an aortic partial occlusion clamp to allow for a hand-sewn anastomosis. The purpose of this multicenter, prospective, randomized trial was to evaluate the efficacy of the PAS-Port device (Cardica, Inc, Redwood City, Calif), which allows an automated proximal anastomosis to be performed without aortic...

متن کامل

Six-month angiographic follow-up of the PAS-Port II clinical trial.

BACKGROUND The PAS-Port device (Cardica, Redwood City, CA) allows the rapid deployment of a clampless proximal anastomosis between a vein graft and the aorta. METHODS Fifty-four patients awaiting elective coronary artery bypass graft surgery were enrolled. Outcome variables were intraoperative device performance, early and 6- month angiographic graft patency, and 12-month clinical follow-up. ...

متن کامل

Five-year clinical outcome and patency rate of device-dependent venous grafts after clampless OPCAB with PAS-port automated proximal anastomosis: the PAPA Study.

OBJECTIVE To evaluate long-term clinical performance and angiographic patency of automated proximal venous anastomoses following clampless coronary artery bypass (C-CAB). METHODS Observational study in patients submitted for isolated C-CAB and at least one proximal aortosaphenous anastomosis performed with an automated connector (Cardica PAS-Port) including 152 consecutive patients (165 devic...

متن کامل

Distal anastomotic patency of the Cardica C-PORT(R) xA system versus the hand-sewn technique: a prospective randomized controlled study in patients undergoing coronary artery bypass grafting.

OBJECTIVES The C-Port® Distal Anastomosis Systems (Cardica, Inc., Redwood City, CA, USA) demonstrated favourable results in feasibility trials. However, distal vein anastomoses created with the C-Port® or C-Port xA® system have never been compared with hand-sewn distal vein anastomoses. The objective of this study was to compare distal end-to-side anastomoses facilitated with the C-Port xA® Sys...

متن کامل

Morphological Evaluation of Proximal Anastomosis by PAS-Port(®) System in Patients with Long-Term Patent Grafts.

PURPOSE We examined grafts employing for morphological analysis of early and long-term results on proximal anastomosis with the PAS-Port(®). METHODS One hundred and four patients treated by OPCAB with PAS-Port(®) were performed postoperative MDCT. Morphological evaluation of the proximal anastomotic region was classified into three groups (A; graft was anastomosed almost perpendicularly to th...