Gender differences in obstructive sleep apnea and treatment response to continuous positive airway pressure.

نویسندگان

  • Lichuan Ye
  • Grace W Pien
  • Sarah J Ratcliffe
  • Terri E Weaver
چکیده

OBJECTIVES Whether gender differences exist in clinical manifestations of obstructive sleep apnea (OSA) and whether women's responses to continuous positive airway pressure (CPAP) are similar to those of men are critical areas of exploration in sleep disordered breathing. This exploratory analysis addressed these questions by examining gender differences over a wide range of clinical outcomes at baseline and in response to CPAP in participants with severe OSA. METHODS Data from 152 men and 24 women who participated in a multicenter CPAP effectiveness study were analyzed. Gender differences in functional status (functional outcomes of sleep questionnaire, sickness impact profile), daytime sleepiness (epworth sleepiness scale, multiple sleep latency test), mood disturbance (profile of mood states), apnea symptoms (multivariable apnea prediction index), and neurobehavioral performance (psychomotor vigilance task) were examined. Treatment response was examined by the change in each outcome from baseline to 3 months after treatment. RESULTS Despite similar age, body mass index, and apnea-hypopnea index, women reported significantly lower functional status, more subjective daytime sleepiness, higher frequency of apnea symptoms, more mood disturbance, and poorer neurobehavioral performance compared to men at baseline. CPAP treatment significantly improved functional status and relieved symptoms for both genders. The magnitude of improvement in each clinical outcome did not vary by gender. CONCLUSIONS Women with OSA showed greater impairment in daytime functioning and symptoms than men. Both genders benefit from CPAP treatment. Adequately powered studies considering possible referral and response bias are necessary to examine gender differences in OSA clinical manifestations and response to CPAP treatment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Factors Affecting Patients’ Adherence to Continuous Positive Airway Pressure Therapy for Obstructive Sleep Apnea Disorder: A Multi-Method Approach

Background: Continuous positive airway pressure (CPAP) is the gold standard therapy for treating obstructive sleep apnea (OSA) disorder. However, patients’ adherence to its regular use is poor. The present study aimed to determine the adherence rate to CPAP therapy by identifying factors affecting its regular use and its associated problems and discomforts among a sample population in Mashhad (...

متن کامل

Effects of Biofeedback Therapy on Cardiovascular and Respiratory Indices in NREM Sleep Parasomnias with Obstructive Sleep Apnea: A Case study

Introduction: Non-REM parasomnias are a relatively common condition in the general human population. Current treatment plans are usually based on small case series and reports. Considering the effects of sleep disorders on different aspects of human life and the failure of pharmacological treatments in this field, the present study was designed to investigate a case of this sleep disorders with...

متن کامل

Myocardial perfusion by myocardial contrast echocardiography and endothelial dysfunction in obstructive sleep apnea.

Obstructive sleep apnea is associated with increased cardiovascular morbidity and mortality. We investigated myocardial perfusion using real-time quantitative myocardial contrast echocardiography with concurrent assessment of macrovascular and microvascular endothelial dysfunction in normotensive subjects with moderate-to-severe obstructive sleep apnea, who were compared with hypertensive and h...

متن کامل

Obstructive Sleep Apnea in Ischemic Stroke patients

OBJECTIVE To investigate the prevalence of obstructive sleep apnea in patients with ischemic stroke and to evaluate the effectiveness of nasal continuous positive airway pressure treatment. METHODS Overnight polysomnography was performed by a computerized system in 19 subjects with ischemic stroke. Patients with an apnea-hypopnea index > or = 5 were considered to have obstructive sleep apnea....

متن کامل

Simultaneous sleep study and nasoendoscopic investigation in a patient with obstructive sleep apnoea syndrome refractory to continuous positive airway pressure: a case report

INTRODUCTION The standard treatment for obstructive sleep apnoea syndrome is nasal continuous positive airway pressure. In most cases the obstruction is located at the oropharyngeal level, and nasal continuous positive airway pressure is usually effective. In cases of non-response to nasal continuous positive airway pressure other treatments like mandibular advancement devices or upper airway s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical sleep medicine : JCSM : official publication of the American Academy of Sleep Medicine

دوره 5 6  شماره 

صفحات  -

تاریخ انتشار 2009