Classification accuracy in multiple color fluorescence imaging microscopy.
نویسندگان
چکیده
BACKGROUND The discriminatory power and imaging efficiency of different multicolor FISH (M-FISH) analysis systems are key factors in obtaining accurate and reproducible classification results. In a recent paper, Garini et al. put forth an analytical technique to quantify the discriminatory power ("S/N ratio") and imaging efficiency ('excitation efficiency') of multicolor fluorescent karyotyping systems. METHODS A parametric model of multicolor fluorescence microscopy, based on the Beer-Lambert law, is analyzed and reduced to a simple expression for S/N ratio. Parameters for individual system configurations are then plugged into the model for comparison purposes. RESULTS We found that several invalid assumptions, which are used to reduce the complex mathematics of the Beer-Lambert law to a simple S/N ratio, result in some completely misleading conclusions about classification accuracy. The authors omit the most significant noise source, and consider only one highly abstract and unrepresentative situation. Unwisely chosen parameters used in the examples lead to predictions that are not consistent with actual results. CONCLUSIONS The earlier paper presents an inaccurate view of the M-FISH situation. In this short communication, we point out several inaccurate assumptions in the mathematical development of Garini et al. and the poor choices of parameters in their examples. We show results obtained with different imaging systems that indicate that reliable and comparable results are obtained if the metaphase samples are well-hybridized. We also conclude that so-called biochemical noise, not photon noise, is the primary factor that limits pixel classification accuracy, given reasonable exposure times.
منابع مشابه
Multicolor Super-Resolution Fluorescence Imaging via Multi-Parameter Fluorophore Detection
Understanding the complexity of the cellular environment will benefit from the ability to unambiguously resolve multiple cellular components, simultaneously and with nanometer-scale spatial resolution. Multicolor super-resolution fluorescence microscopy techniques have been developed to achieve this goal, yet challenges remain in terms of the number of targets that can be simultaneously imaged ...
متن کاملMultiple color single molecule TIRF imaging and tracking of MAPs and motors.
Microtubules are part of a complex mechano-chemical network inside cells. In order to understand how the components of these systems work together, careful in vitro experiments must be performed with added complexity. These experiments can ideally image all the interacting species. In order to image these molecules, multiple-color fluorescence imaging can be performed. In this chapter, we descr...
متن کاملVirtual Hematoxylin and Eosin Transillumination Microscopy Using Epi-Fluorescence Imaging
We derive a physically realistic model for the generation of virtual transillumination, white light microscopy images using epi-fluorescence measurements from thick, unsectioned tissue. We demonstrate this technique by generating virtual transillumination H&E images of unsectioned human breast tissue from epi-fluorescence multiphoton microscopy data. The virtual transillumination algorithm is s...
متن کاملA Thin Layer Imaging with the Total Internal Reflection Fluorescence Microscopy
Total internal reflection fluorescence microscopy (TIRFM) is an optical technique that allows imaging of a thin layer of the sample with a thickness of about 100-200 nm. It is used in science of cell biology to study cellular processes, especially near the membranes of living cells. This method is based on the total internal reflection phenomenon, where the evanescent wave is generated in the l...
متن کاملHigh resolution spectral self-interference fluorescence microscopy
We present a new method of fluorescence imaging, which yields nm-scale axial height determination and ~15 nm axial resolution. The method uses the unique spectral signature of the fluorescent emission intensity well above a reflecting surface to determine vertical position unambiguously. We have demonstrated axial height determination with nm sensitivity by resolving the height difference of fl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Cytometry
دوره 41 2 شماره
صفحات -
تاریخ انتشار 2000