ar X iv : p hy si cs / 0 60 52 34 v 2 6 S ep 2 00 6 Theory of double resonance magnetometers based on atomic alignment

نویسنده

  • Anatoly S. Pazgalev
چکیده

We present a theoretical study of the spectra produced by optical/radio-frequency double resonance devices, in which resonant linearly polarized light is used in the optical pumping and detection processes. We extend previous work by presenting algebraic results which are valid for atomic states with arbitrary angular momenta, arbitrary rf intensities, and arbitrary geometries. The only restriction made is the assumption of low light intensity. The results are discussed in view of their use in optical magnetometers.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ar X iv : p hy si cs / 0 60 90 14 v 2 9 N ov 2 00 6 Limit on the Temporal Variation of the Fine - Structure Constant Using Atomic

A. Cingöz, A. Lapierre, A.-T. Nguyen, N. Leefer, D. Budker, 3 S. K. Lamoreaux, ∗ and J. R. Torgerson Department of Physics, University of California at Berkeley, Berkeley, California 94720-7300, USA Los Alamos National Laboratory, Physics Division, P-23, MS-H803, Los Alamos, New Mexico 87545, USA Nuclear Science Division, Lawrence Berkeley National Laboratory, Berkeley, California 94720, USA (D...

متن کامل

ar X iv : p hy si cs / 0 51 00 49 v 2 1 5 M ar 2 00 6 Mass Measurements and the Bound – Electron g Factor ∗

The accurate determination of atomic masses and the high-precision measurement of the bound-electron g factor are prerequisites for the determination of the electron mass, which is one of the fundamental constants of nature. In the 2002 CODATA adjustment [P. J. Mohr and B. N. Taylor, Rev. Mod. Phys. 77, 1 (2005)], the values of the electron mass and the electron-proton mass ratio are mainly bas...

متن کامل

ar X iv : p hy si cs / 0 60 40 11 v 1 3 A pr 2 00 6 On orbit alignment and diagnostics for the LISA Technology Package

This paper presents a procedure to perform fully autonomous on orbit alignment of the interferometer on board the LISA technology package (LTP). LTP comprises two freefloating test masses as inertial sensors that additionally serve as end-mirrors of a set of interferometers. From the output signals of the interferometers, a subset has been selected to obtain alignment information of the test ma...

متن کامل

ar X iv : p hy si cs / 0 60 52 00 v 1 2 3 M ay 2 00 6 An accurate optical lattice clock with 87 Sr atoms

We report a frequency measurement of the 1S0− 3P0 transition of Sr atoms in an optical lattice clock. The frequency is determined to be 429 228 004 229 879 (5)Hz with a fractional uncertainty that is comparable to state-of-the-art optical clocks with neutral atoms in free fall. Two previous measurements of this transition were found to disagree by about 2× 10, i.e. almost four times the combine...

متن کامل

ar X iv : p hy si cs / 0 60 51 63 v 3 6 J ul 2 00 6 Frequency shift of hyperfine transitions due to blackbody radiation

We have performed calculations of the size of the frequency shift induced by a static electric field on the clock transition frequencies of the hyperfine splitting in Yb, Rb, Cs, Ba, and Hg. The calculations are used to find the frequency shifts due to blackbody radiation which are needed for accurate frequency measurements and improvements of the limits on variation of the fine structure const...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006