OBJECTIVE This study aimed to compare the stability of Tile C pelvic fractures fixed with two iliosacral (IS) screws, tension band plate (TBP), and minimally invasive adjustable plate (MIAP). METHODS Six embalmed specimens of adult pelvis were used. The soft tissue was removed from the specimens, but spines from the fourth lumbar vertebra to the proximal one-third of both femurs were retained. The pubic symphysis, bilateral sacroiliac joints and ligaments, bilateral hip joints, bilateral sacrotuberous ligaments, and bilateral sacrospinous ligaments were intact. Tile C pelvic fractures were created on the specimens. The symphysis pubis was fixed with a plate, and the fracture on the posterior pelvic ring was fixed with three types of internal fixation in a randomized block design. The specimens were placed in a biomechanical machine at a standing neutral posture. A cyclic vertical load of up to 500N was applied, and displacement was recorded. Shifts in the fracture gap were measured by a grating displacement sensor. RESULTS Under different vertical loads, the shift in the fracture gap and displacement of the pelvic fractures fixed with two IS screws were similar to those in fractures fixed with MIAP. However, the shift in the fracture gap and displacement of fractures fixed with MIAP was significantly smaller than those of fractures fixed with TBP. CONCLUSION The stability of the Tile C pelvic fractures fixed with MIAP was similar to that of fractures fixed with IS screws. MIAP performed better than TBP under vertical load.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The functional outcome of surgically treated unstable pelvic ring fractures by open reduction, internal fixation

 Abstract Background: Unstable Pelvic fracture, a result of high energy antero-posterior compression injury, has been managed based on internal fixation and open reduction. The mode of fixation in Unstable Pelvic fracture has, however, been a subject of controversy and some authors have proposed a need to address the issue of partial breach of the pelvic ring elements in these injuries. This st...

متن کامل

Biomechanical Comparison of Two Kinds of Internal Fixation in a Type C Zone II Pelvic Fracture Model

BACKGROUND Unstable pelvic fractures are complex and serious injuries. Selection of a fixation method for these fractures remains a challenging problem for orthopedic surgeons. This study aimed to compare the stability of Tile C pelvic fractures fixed with two iliosacral (IS) screws and minimally invasive adjustable plate (MIAP) combined with one IS screw. METHODS This study was a biomechanic...

متن کامل

Parallel analysis of finite element model controlled trial and retrospective case control study on percutaneous internal fixation for vertical sacral fractures

BACKGROUND Although percutaneous posterior-ring tension-band metallic plate and percutaneous iliosacral screws are used to fix unstable posterior pelvic ring fractures, the biomechanical stability and compatibility of both internal fixation techniques for the treatment of Denis I, II and III type vertical sacral fractures remain unclear. METHODS Using CT and MR images of the second generation...

متن کامل

Clinical Results of Percutaneous Fixation of Pelvic and Acetabular Fractures: A Minimally Invasive Internal Fixation Technique

Background: The pelvic ring fractures (PRF) and acetabular fractures (AF) are among the major orthopedic injuriesassociated with high rates of morbidity and mortality. Open surgical stabilization is the standard treatment for themajority of these complications. Percutaneous minimally invasive surgical stabilization of the fractures has become anaccepted treatment method for th...

متن کامل

Biomechanical stability of a supra-acetabular pedicle screw Internal Fixation device (INFIX) vs External Fixation and plates for vertically unstable pelvic fractures

BACKGROUND We have recently developed a subcutaneous anterior pelvic fixation technique (INFIX). This internal fixator permits patients to sit, roll over in bed and lie on their sides without the cumbersome external appliances or their complications. The purpose of this study was to evaluate the biomechanical stability of this novel supraacetabular pedicle screw internal fixation construct (INF...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International journal of clinical and experimental medicine

دوره 8 2  شماره 

صفحات  -

تاریخ انتشار 2015