High Voltage Insulator Contamination Level Monitoring with X- Band Microwave Radiometer

نویسندگان

  • Yan JIANG
  • Alistair REID
  • Azam NEKAHI
  • Scott G MCMEEKIN
  • Martin JUDD
  • Alan WILSON
چکیده

This paper introduces a novel method for monitoring contamination levels on high voltage insulators based on microwave radiometry. The microwave radiometer described measures energy emitted from the contamination layer and could provide a safe, reliable, contactless monitoring method that is effective under dry conditions. The relationship between equivalent salt deposit density and radiometer output is described using a theoretical model and experimentally verified using a specially designed X-band radiometer. Results demonstrate that the output from the radiometer is able to clearly distinguish between samples with different contamination levels under dry conditions. This novel contamination monitoring method could potentially provide advance warning of the future failure of wet insulators in climates where insulators can experience dry conditions for extended periods.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Radiometer Development of an Agile Digital Detector for RFI Detection and Mitigation on Spaceborne Radiometers

A new type of microwave radiometer detector has been developed that is capable of identifying high and low levels of Radio Frequency Interference (RFI) and of reducing or eliminating its effect on the measured brightness temperatures. The Agile Digital Detector (ADD) digitizes its pre-detection radiometer signal, performs digital sub band filtering, and then measures the first four moments of t...

متن کامل

Time-Resolved Photoresponse in the Resistive Flux-Flow State in Y-Ba-Cu-O Superconducting Microbridges

186 LLE Review, Volume 95 Introduction High-temperature superconductors (HTS’s) exhibit many properties that are very desirable for microwave-based telecommunication applications. Their main advantages are low absorption at microwave frequencies1 and existence of HTS microwave devices based on the controlled vortex flux flow.2 The mostpromising material is the YBa2Cu3O7–x (YBCO) superconductor ...

متن کامل

Development of an Agile Digital Detector for RFI Detection and Mitigation on Spaceborne Radiometers

A new type of microwave radiometer detector has been developed that is capable of identifying low level Radio Frequency Interference (RFI) and of reducing or eliminating its effect on the measured brightness temperature. The Agile Digital Detector (ADD) can discriminate between RFI and natural thermal emission signals by directly measuring other moments of the signal than the variance that is t...

متن کامل

Design and Development of a Ground-based Microwave Radiometer System

This paper presents the design and development of a ground-based microwave radiometer system (MWR) for the offshore oil platform. It will be used to provide long time series of geophysical parameters such as the sea-surface temperature, the near-surface wind speed and the sea ice type. The ground-based MWR is a five-frequency, dual-polarized microwave radiometer which is a total power type micr...

متن کامل

Description and Performance of an L-Band Radiometer with Digital Beamforming

This paper presents the description and performance tests of an L-band microwave radiometer with Digital Beamforming (DBF), developed for the Passive Advanced Unit (PAU) for ocean monitoring project. PAU is an instrument that combines, in a single receiver and without time multiplexing, a microwave radiometer at L-band (PAU-RAD) and a GPS-reflectometer (PAU-GNSS-R). This paper focuses on the PA...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015