Development and Applications of C-scan Ultrasonic Facility
نویسندگان
چکیده
This paper presents the in-house development and application of a C-scan ultrasonic facility ULTIMA 200M2 at the Indira Gandhi Centre for Atomic Research (IGCAR), Kalpakkam, carried out in collaboration with the Electronics Division, Bhabha Atomic Research Centre (BARC), Mumbai. The paper describes various constituents of the system developed and also highlights the typical results obtained using this system, including bond integrity assessment of explosive welds and imaging of fuel sub-assembly heads of the Fast Breeder Test Reactor. The system has also been used for imaging both the sides of a one rupee Indian coin. All the finer details of the coin could be extracted, demonstrating the resolution capabilities of the system.
منابع مشابه
Accuracy Assessment of Ultrasonic C-scan and X-ray Radiography Methods for Impact Damage Detection in Glass Fiber Reinforced Polyester Composites
The present study introduces two quantitative parameters to compare the accuracy of ultrasonic C-scan testing and X-ray radiography methods in the damaged area detection under low-velocity impact in polymer-based composites. For this purpose, the hand lay-up technique of composite processing was employed to prepare the composite specimen. A composite specimen consisting of the glass fiber reinf...
متن کاملطراحی و ساخت روبشگر فراصوتی جهت تهیه تصاویر روبش B (B-Scan) از قطعات صنعتی
The results of ultrasonic tests are usually displayed as A-scan signals. In an A-scan signal, reflections of ultrasonic wave form different reflectors are shown as sharp echoes on a time by amplitude display. Interpretation of these echoes can sometimes be quite difficult and usually requires knowledgeable and experienced specialists. There exist other methods of displaying the ultrasonic test...
متن کاملSynthesis of TiO2-ZnO-ZrO2 Nanocomposites for Nonlinear Optics Applications
A sol-gel technique under ultrasonic irradiation was applied to synthesize ZrO2/TiO2/ZnOnanocomposites. X-ray diffraction analysis confirmed the successful synthesis of nanocomposites. The strain and crystalline size values of ZrO2/TiO2/ZnO nanocomposites are estimated to be 9.98×10-4 and 17.66 nm, respectively. The linear absorption coefficient of ZrO2/TiO2/ZnO nanocomposites was measure...
متن کاملC-scan ultrasonography in orbital diagnosis.
A C-scan imaging facility has recently been added to the ultrasonic system in use at Moorfields Eye Hospital, London. The technique is explained and typical C-scans are presented to demonstrate the normal orbital fat and optic nerve, together with selected pathological conditions in the orbit. The C-scan facility permits imaging of the orbital contents in the coronal plane. This coronal plane i...
متن کاملApplications of two new algorithms of cuckoo optimization (CO) and forest optimization (FO) for solving single row facility layout problem (SRFLP)
Nowadays, due to inherent complexity of real optimization problems, it has always been a challenging issue to develop a solution algorithm to these problems. Single row facility layout problem (SRFLP) is a NP-hard problem of arranging a number of rectangular facilities with varying length on one side of a straight line with aim of minimizing the weighted sum of the distance between all facility...
متن کامل