The influence of the label on the quality of a solid-phase immunoassay: evaluation of a commercial ELISA kit for serum ferritin.

نویسندگان

  • H A Assink
  • H J Brouwer
  • B G Blijenberg
  • B Leijnse
چکیده

A new Enzyme Linked Immuno Sorbent Assay (ELISA) kit for the determination of serum ferritin has been compared with another ferritin kit based on the Immuno Radio-Metric Assay (IRMA) approach, both assays containing similar antibodies. Based on these studies, we found the within-run precision of the ELISA (and IRMA) to have coefficients of variation of 4-10% and 2-6% respectively, over a concentration range of 12-600 micrograms/l. The between-run precision for the same concentration range exhibited a CV range of 9-13% and 7-11% respectively. The sensitivities were found to be 1.4 micrograms/l and 0.9 microgram/l. The mean recovery was 103% for the ELISA procedure. It was found that, using the serum dilution technique, the linearity reached to 1000 micrograms/l. In the ELISA procedure no influence from the so-called "high dose hook effect" was observed. While EDTA-plasma produced 6% lower values than serum in the ELISA technique, no interference from albumin, gamma-globulins and mild haemolysis was observed. Stability problems with the ELISA kit were not encountered. A comparative analysis of multiple specimens demonstrated nearly identical values with r = 0.994 and y = 0.87 x1.01. The quality and ease of operation of the ELISA approach compared with other techniques are discussed. In conclusion it is possible to replace a radio-label in an immunoassay with an enzyme-label with the same degree of reliability and other parameters of quality control exhibited by radioimmunoassays.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

DEVELOPMENT OF A SIMPLE AND SENSITIVE ENZYME- LINKED IMMUNOSORBENT ASSAY (ELISA) FOR CLINICAL MEASUREMENT OF TESTOSTERONE USING PENICILLINASE AS LABEL

An enzyme-linked immunosorbent assay using a homologous combination of antiserum raised against testosterone-3-0-carboxymethyloxime-bovine serum albumin (T-3-0-CMO-BSA ) and penicillinase-labelled T-3-0-CMO was developed. This assay was utilized to measure testosterone in serum samples of male and female subjects. The sensitivity of the assay is 50pg/well and the antibody developed crossrea...

متن کامل

Evaluation of a New Anti-HIV1/2 ELISA–HIV 1/2 REC Diagnostic Kit Based on E. coli Derived Soluble Recombinant Proteins: Ex-perience of an International Study

Background/Objective: Development of a new enzyme-linked immunosorbent assay (ELISA) for screening human blood serum and plasma for antibodies to human immunodeficiency virus type 1 (HIV1) and type 2 (HIV2) as HIV1/2REC ELISA diagnostic kit based on E. coli derived soluble recombinant proteins. Methods: Polypeptides corresponding to HIV1 gp41 and HIV2 gp36 immunodominant regions and HIV1 gag we...

متن کامل

Positive interference in Radioimmunoassay determination of serum total T3

Introduction: Determination of thyrotropin, total and free thyroxine and triiodothyronine are widely used as diagnostic methods for thyroid function evaluation. There have been numerous reports of interferences in thyroid hormone immunoassays. Herein, a prominent positive interference is reported for a radioimmunoassay kit of total triiodothyronine. Materials and Methods: In this study, a total...

متن کامل

Serum levels of iron parameters and IL-17 in children with Helicobacter pylori infection compared to healthy group

Helicobacter pylori is related to iron deficiency anemia (IDA) and inflammatory responses causing gastric and duodenal ulcer and carcinoma. Moreover, it leads to deficiency of factors associated with iron adsorption and transfer. In the present study, we recruited 100 children (50 infected with H. pylori and 50 controls) aged 3-14 years old (40% male and 60% female) to evaluate the effect of H....

متن کامل

Evaluation of Serum Ferritin Levels and its Relation with Severity and Duration of Hospitalization in Heart Failure Patients Admitted in Ganjavian Hospital, Ahvaz, Iran

Background: Cardiovascular diseases are one of the most common chronic illnesses. Despite the advancement in the management of heart failure, it still remains as one of the most important causes of mortality and morbidity. Anemia is a common finding in heart failure patients and decreases both life quality and bodily function in this group of patients. It is also related with high mortality and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical chemistry and clinical biochemistry. Zeitschrift fur klinische Chemie und klinische Biochemie

دوره 21 11  شماره 

صفحات  -

تاریخ انتشار 1983