Comparison of left ventricular ejection fraction values obtained using invasive contrast left ventriculography, two-dimensional echocardiography, and gated single-photon emission computed tomography
نویسندگان
چکیده
OBJECTIVES Left ventricular ejection fraction can be measured by a variety of invasive and non-invasive cardiac techniques. This study assesses the relation of three diagnostic modalities to each other in the measurement of left ventricular ejection fraction: invasive contrast left ventriculography, two-dimensional echocardiography, and quantitative gated single-photon emission computed tomography. METHODS Retrospective chart review was conducted on 58 patients hospitalized with chest pain, who underwent left ventricular ejection fraction evaluation using each of the aforementioned modalities within a 3-month period not interrupted by myocardial infarction or revascularization. RESULTS The mean left ventricular ejection fraction values were as follows: invasive contrast left ventriculography (0.44±0.15), two-dimensional echocardiography (0.46±0.13), and gated single-photon emission computed tomography (0.37±0.10). Correlations coefficients and associated p values were as follows: invasive contrast left ventriculography versus two-dimensional echocardiography (r=0.69, p<0.001), invasive contrast left ventriculography versus gated single-photon emission computed tomography (r=0.80, p<0.0001), and gated single-photon emission computed tomography versus two-dimensional echocardiography (r=0.69, p<0.001). CONCLUSION Our results indicate that strong positive correlations exist among the three techniques studied.
منابع مشابه
Prediction of Changes in Left Ventricular Ejection Fraction after Off-Pump Coronary Artery Bypass Grafting Surgery by Myocardial Perfusion Single-Photon Emission Computed Tomography
Introduction: Left ventricular ejection fraction (LVEF) is considered to be the single most important prognostic factor in patients with previous myocardial infarction. LVEF is not improved in all patients after coronary artery bypass grafting (CABG). This study aimed to assess the possibility of prediction of LVEF changes after CABG using myocardial perfusion gated signle photon emission compu...
متن کاملLeft Ventricular Ejection Fraction: a Retrospective Study Comparing 2d Echocardiography and Gated Single Photon Emission Computed Tomography (spect) in Clinical Use
Objectives The aim of this study was to compare left ventricular ejection fraction (LVEF) results derived from gated single photon emission computed tomography (SPECT) using Cedars-Sinai quantitative gated SPECT (QGS) processing software with results from 2D echocardiography, both obtained in routine clinical diagnostic use. Methods Data from previously performed tests were obtained from 73 pat...
متن کاملAccuracy of cardiac CT, radionucleotide and invasive ventriculography, two- and three-dimensional echocardiography, and SPECT for left and right ventricular ejection fraction compared with cardiac MRI: a meta-analysis.
AIMS Left ventricular ejection fraction (LVEF) and right ventricular ejection fraction (RVEF) are important tools in clinical decision-making. We hypothesized that two-dimensional echocardiography (2DE), three-dimensional echocardiography (3DE), radionucleotide ventriculography (RNV), cardiac computed tomography (CT), gated single-photon emission CT (SPECT), and invasive cardiac cine ventriculo...
متن کاملAssessment of global and regional left ventricular function by electrocardiographic gated N-13 ammonia positron emission tomography in patients with coronary artery disease.
BACKGROUND Electrocardiographic gated 13N-ammonia positron emission tomography (PET) enables simultaneous assessment of myocardial blood flow and left ventricular (LV) function. The aim of this study was to assess the accuracy of gated 13N-ammonia PET for evaluating global and regional LV function in patients with coronary artery disease (CAD) in comparison with conventional left ventriculograp...
متن کاملSingle photon emission computed tomography: An alternative imaging modality in left ventricular evaluation
Various diagnostic imaging modalities have been used for quantitative left ventricular (LV) parameters. Because of the suboptimal value of the most widely used technology, two-dimensional (2D) echocardiography, 3D ultrasonographic imaging has improved accuracy for LV volume and function. Single photon emission computed tomography (SPECT) is another diagnostic method where LV volumetric and func...
متن کامل