Side view thrombosis microfluidic device with controllable wall shear rate and transthrombus pressure gradient.
نویسندگان
چکیده
Hemodynamic conditions vary throughout the vasculature, creating diverse environments in which platelets must respond. To stop bleeding, a growing platelet deposit must be assembled in the presence of fluid wall shear stress (τw) and a transthrombus pressure gradient (ΔP) that drives bleeding. We designed a microfluidic device capable of pulsing a fluorescent solute through a developing thrombus forming on collagen ± tissue factor (TF), while independently controlling ΔP and τw. Computer control allowed step changes in ΔP with a rapid response time of 0.26 mm Hg s(-1) at either venous (5.2 dynes cm(-2)) or arterial (33.9 dynes cm(-2)) wall shear stresses. Side view visualization of thrombosis with transthrombus permeation allowed for quantification of clot structure, height, and composition at various ΔP. Clot height was reduced 20% on collagen/TF and 28% on collagen alone when ΔP was increased from 20.8 to 23.4 mm Hg at constant arterial shear stress. When visualized with a platelet-targeting thrombin sensor, intrathrombus thrombin levels decreased by 62% as ΔP was increased from 0 to 23.4 mm Hg across the thrombus-collagen/TF barrier, consistent with convective removal of thrombogenic solutes due to pressure-driven permeation. Independent of ΔP, the platelet deposit on collagen had a permeability of 5.45 × 10(-14) cm(2), while the platelet/fibrin thrombus on collagen/TF had a permeability of 2.71 × 10(-14) cm(2) (comparable to that of an intact endothelium). This microfluidic design allows investigation of the coupled processes of platelet deposition and thrombin/fibrin generation in the presence of controlled transthrombus permeation and wall shear stress.
منابع مشابه
Blood clots are rapidly assembled hemodynamic sensors: flow arrest triggers intraluminal thrombus contraction.
OBJECTIVE Blood clots form under flow during intravascular thrombosis or vessel leakage. Prevailing hemodynamics influence thrombus structure and may regulate contraction processes. A microfluidic device capable of flowing human blood over a side channel plugged with collagen (± tissue factor) was used to measure thrombus permeability (κ) and contraction at controlled transthrombus pressure dro...
متن کاملMechanical mechanisms of thrombosis in intact bent microvessels of rat mesentery.
The hypothesis that thrombus can be induced by localized shear stresses/rates, such as in the bent/stretched microvessels, was tested both experimentally and computationally. Our newly designed in vivo experiments were performed on the microvessels (post-capillary venules, 20-50 microm diameter) of rat mesentery. These microvessels were bent/stretched with no/minimum injuries. In less than 60 m...
متن کاملThrombus growth and embolism on tissue factor-bearing collagen surfaces under flow: role of thrombin with and without fibrin.
OBJECTIVE At sites of vascular injury, thrombin is an important mediator in thrombus growth and stability. Using microfluidic flow devices as well as patterned surfaces of collagen and tissue factor (TF), we sought to determine the role that fibrin plays in clot stability without interfering with the production of thrombin. METHODS AND RESULTS We deployed an 8-channel microfluidic device to s...
متن کاملAn Investigation on Platelet Transport during Thrombus Formation at Micro-Scale Stenosis
This paper reports on an investigation of mass transport of blood cells at micro-scale stenosis where local strain-rate micro-gradients trigger platelet aggregation. Using a microfluidic flow focusing platform we investigate the blood flow streams that principally contribute to platelet aggregation under shear micro-gradient conditions. We demonstrate that relatively thin surface streams locate...
متن کاملFibrin, γ'-fibrinogen, and transclot pressure gradient control hemostatic clot growth during human blood flow over a collagen/tissue factor wound.
OBJECTIVE Biological and physical factors interact to modulate blood response in a wounded vessel, resulting in a hemostatic clot or an occlusive thrombus. Flow and pressure differential (ΔP) across the wound from the lumen to the extravascular compartment may impact hemostasis and the observed core/shell architecture. We examined physical and biological factors responsible for regulating throm...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Lab on a chip
دوره 13 10 شماره
صفحات -
تاریخ انتشار 2013