Phakic anterior chamber intraocular lens (Verisyse™) implantation in children for treatment of severe ansiometropia myopia and amblyopia: Six-month pilot clincial trial and review of literature
نویسندگان
چکیده
PURPOSE The current study aims to evaluate both safety and efficacy of Verisyse() (AMO, Irvine, CA) phakic anterior chamber intraocular lens (IOL) in the reduction of clinically significant (>-8 D) myopic anisometropia in children who are noncompliant to traditional medical treatment including spectacle correction or contact lenses. DESIGN Retrospective interventional case series. METHODS Six anisometropic myopic pediatric patients in one practice were identified through chart-review. None of the patients were compliant with specatacle correction or contact lens wear and as a result had dense amblyopia of less than 20/400 by Snellen or Allen visual acuity (mean <20/400). All patients underwent Verisyse() phakic IOL implantation in the more myopic eye by one surgeon (AP). Pre- and post-operative visual acuity, anterior/posterior segment examination, stereoacuity, axial biometry measurements, cycloplegic refraction, and endothelial cell counts were performed in all patients whenever feasible. RESULTS The age of patients ranged from 5-11 years. The mean post-operative follow-up time was six months from the time of IOL insertion. Improvement in visual acuity >6 lines was achieved in four patients (mean visual acuity of 20/70 at six months). Improvement in stereoacuity was noted in all six patients (from total mean zero seconds-arc to six-months post-operative mean of 500 seconds-arc by randot stereoacuity testing). Improvement of >2 lines of visual acuity lines was achieved in the other two patients. No patient lost any lines of visual acuity. Enhanced physical activity, coordination, and improved social interaction were noted in patients and were reported by the parents. No intra/post-operative complications were noted. DISCUSSION Irreversible or intractable amblyopia secondary to severe anisometropic myopia is a serious medical concern in the pediatric population. Failure of compliance with contact lens therapy consistently leads to visual loss. Anterior chamber phakic IOLs may provide a safe alternative in treatment of noncompliant anisometropic myopic patients who do not accept spectacle wear or contact lens therapy. CONCLUSION To reduce or eliminate highly significant anisometropic myopia in children who are noncompliant with traditional medical treatment, phakic anterior chamber IOL implantation may be considered as an alternative modality of treatment.
منابع مشابه
OPTH-5710-Phakic anterior chamber intraocular lens - Verisyse
Correspondence: Amir Pirouzian 710 Lawerence Expressway, Dept 490, Santa Clara, CA 95051, USA Tel +1 408 851 4100 Email [email protected] Purpose: The current study aims to evaluate both safety and efficacy of VerisyseTM (AMO, Irvine, CA) phakic anterior chamber intraocular lens (IOL) in the reduction of clinically significant (-8 D) myopic anisometropia in children who are noncompliant to...
متن کاملThe Role of Phakic Intraocular Lens Implants in Treatment of High-Refractive Errors and Amblyopia in Children
INTRODUCTION This article aims to evaluate the role of phakic intraocular lens (pIOL) implants in the treatment of high-refractive errors and amblyopia in the pediatric setting. METHODS A literature search of the PubMed database was conducted in December 2012 using the keywords: pIOL implants, amblyopia, pediatric refractive surgery and ametropia, and articles of high or medium clinical relev...
متن کاملPediatric phakic intraocular lens surgery: review of clinical studies.
PURPOSE OF REVIEW To report on the accumulating peer-reviewed data of phakic intraocular lens (pIOL) implantation in the pediatric population. I evaluate and compare the published peer-reviewed articles for the reported efficacy and complications of phakic intraocular lens implantations in children for correction of clinically significant high refractive errors. RECENT FINDINGS Multiple studi...
متن کاملVisual Improvement in High Myopic Amblyopic Adult Eyes following Phakic Anterior Chamber Intraocular Lens Implantation
PURPOSE To evaluate the efficacy and safety of angle-supported phakic anterior chamber intraocular lenses in amblyopic adult eyes with very high myopia. METHODS We evaluated 12 eyes in nine patients with very high myopic amblyopia who received angle-supported phakic intraocular lenses (Phakic 6H) and followed them for more than six months. Uncorrected visual acuity (UCVA), best-corrected visu...
متن کاملReversal of myopic anisometropic amblyopia with phakic intraocular lens implantation.
PURPOSE To report a case of reversal of myopic anisometropic amblyopia with phakic intraocular lens implantation. METHODS A 6-year-old boy with anisometropic amblyopia with spherical equivalent refraction of right eye: -14.00 -3.00 x 100 degrees, left eye: -0.50 -3.25 x 90 degrees, was treated for 2 years with occlusion to the left eye, with poor results. Refractive surgery was planned becaus...
متن کامل