A modified technique of using the dynamic external finger fixation system. Case study.
نویسندگان
چکیده
Fractures of the phalangeal joints of the hand present a challenging problem because of the small size of the fracture fragments, limiting internal fixation, and their articular nature necessitating early mobilisation to ensure good results. We present a case of a patient presenting with an open displaced intraarticular fracture of the metacarpophalangeal joint that was managed with limited internal fixation with a Kirschner wire along with the S-Quattro. The fracture united and the patient returned to his previous occupation with no limitations in his activities of daily living. This is the first instance of S-Quattro being described for the management of an open fracture with the additional use of limited internal fixation. The additional use of limited internal fixation ensured adequate fracture reduction and stabilisation. The S-Quattro application does not require significant soft tissue dissection, making it particularly suited to open fractures.
منابع مشابه
Modified Internal Fixation Technique for Acromio-Clavicular (AC) joint dislocation: The “Hidden Knot Technique”
Acromioclavicular (AC) joint injuries are common and often seen in contact athletes, resulting from a fall on the shouldertip with adducted arm. This joint is stabilized by both static and dynamic structures including the coracoclavicular (CC)ligament. Most reconstruction techniques focus on CC ligament augmentation as the primary stabilizer of the AC joint.The best surgical technique for some ...
متن کاملDynamic modeling and control of a 4 DOF robotic finger using adaptive-robust and adaptive-neural controllers
In this research, first, kinematic and dynamic equations of a 4-DOF 3-link robotic finger are derived using Denavit-Hartenberg convention and Lagrange’s formulation. To model the muscles, several springs and dampers are placed between the finger links. Then, two advanced controllers, namely adaptive-robust and adaptive-neural, which can control the robotic finger in presence of parametric uncer...
متن کاملMODIFIED ONE- FINGER LAPAROSCOPY TECHNIQUE
We used the modified one finger laparoscopy technique on 100 patients and found it to be successful in 87% of cases. No major complication occurred during or after such operations. However, we think that this technique is accompanied by three important problems: 1) The CO2 gas is lost f1"om the subumbilical incision, 2) A secondary fascial layer is present in some patients, and 3) There i...
متن کاملDynamic Distraction External Fixation Derived from the SUZUKI Frame for PIP Joint Fractures
How to cite this article Boussakri H, Elibrahimi A and Elmrini A. Dynamic Distraction External Fixation Derived from the SUZUKI Frame for Pip Joint Fractures. SM J Orthop. 2015;1(5):1025. OPEN ACCESS ISSN: 2473-067X Letter to the Editor We present a case of an unstable proximal interphalangeal fracture of the fifth finger. We want to review the treatment of this entity, by using a dynamic exter...
متن کاملDetermination of Composite System Adequacy Equivalents Using a Reduction Technique: a Case Study on a Regional Electric Company
Reliability evaluation of a large-scale composite power system faces to numerous events/outage and consequently imposes an extensive burden of calculations. In order to simplify the problem, determination of an equivalent system for large-scale power system is inevitable. This paper proposes a framework as reduction technique to separate a composite power system to three areas: external area, o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Ortopedia, traumatologia, rehabilitacja
دوره 13 4 شماره
صفحات -
تاریخ انتشار 2011