The X-ray CCD camera of the MAXI Experiment on the ISS/JEM

نویسندگان

  • E. Miyata
  • H. Tsunemi
  • T. Mihara
  • H. Negoro
چکیده

MAXI, Monitor of All-sky X-ray Image, is the X-ray observatory on the Japanese experimental module (JEM) Exposed Facility (EF) on the International Space Station (ISS). MAXI is a slit scanning camera which consists of two kinds of X-ray detectors: one is a one-dimensional position-sensitive proportional counter with a total area of ∼ 5000 cm, the Gas Slit Camera (GSC), and the other is an X-ray CCD array with a total area ∼ 200 cm, the Solid-state Slit Camera (SSC). The GSC subtends a field of view with an angular dimension of 1◦× 180◦ while the SSC subtends a field of view with an angular dimension of 1◦ times a little less than 180◦. In the course of one station orbit, MAXI can scan almost the entire sky with a precision of 1◦ and with an X-ray energy range of 0.5−30 keV. We have developed the engineering model of CCD chips and the analogue electronics for the SSC. The energy resolution of EM CCD for Mn Kα has a full-width at half maximum of ≃ 182 eV. Readout noise is ≃ 11 e−rms.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Response Builders of MAXI X-ray Slit Cameras and Simulator

MAXI, an all-sky X-ray monitor to be on-board on the ISS (International Space Station), carries two kinds of X-ray cameras: GSC (Gas Slit Camera) and SSC (Solid-state Slit Camera). Both X-ray cameras are scanning imagers combining position-sensitive detectors and collimators with one-dimensional FOV (field of view). They covers 90% of the whole sky every 90 minutes of the ISS orbital period. Th...

متن کامل

The perceptibility curve test applied to CCD and two methods of digitization of dental film-based radiographs

Objectives: Several methods of image acquisition are accessible in dentistry. There is no overall acceptable method for image digitization so all different types of images can be comparable. The objective of this study was to compare the diagnostic accuracy of different methods of image digitization. Methods: This accuracy diagnostic test study used perceptibility curve test which first intr...

متن کامل

EFFECT OF NOZZLE DIAMETER AND ATOMIZING AIR PRESSURE ON CHARACTERISTICS OF IN-FLIGHT PARTICLES IN WIRE ARC SPRAYING

In wire arc spraying, the atomizing air pressure and applied nozzle system are important factors influencing particles characteristics and coating quality. The aim of this paper is to study how the characteristics of particles such as size, velocity and temperature are influenced by the operating conditions in wire arc spray. For that, three types of wires are tested: solid wire of stainless st...

متن کامل

Diagnostic Value of Ischial Spine Sign in Patients with Acetabular Retroversion

Background: Acetabular Retroversion (AR) is a hip disorder and one of the causes of pain in this area. Evaluationof positive Cross Over Sign (COS) on AP X-Rays of the hip is currently the best method of diagnosis of AR. Severalstudies have measured co-existence of Ischial Spine Sign (ISS) in patients with AR. In this study we evaluated thediagnostic value of ISS in confirmation of AR and compar...

متن کامل

Area x-ray detector based on a lens-coupled charge-coupled device

An area x-ray detector constructed using commercially available “off-the-shelf” parts is described and its performance is characterized. The detector consists of a 1024 1024 pixel charge-coupled device CCD camera optically coupled to x-ray sensitive phosphor screen using a standard 35 mm camera lens. The conversion efficiency, spatial nonuniformity, spatial resolution and the detective quantum ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1999