Injection pain and postinjection pain of the anterior middle superior alveolar injection administered with the Wand or conventional syringe.

نویسندگان

  • John Nusstein
  • Shelly Lee
  • Al Reader
  • Mike Beck
  • Joel Weaver
چکیده

OBJECTIVE The purpose of this prospective, randomized, blinded study was to compare the pain of injection and post-injection pain of the AMSA injection using the computer-assisted Wand Plus injection system versus a conventional syringe. STUDY DESIGN Using a crossover design, 40 subjects randomly received 2 blinded AMSA injections using the Wand Plus system and a conventional syringe, at 2 separate appointments. The AMSA injection site was centered halfway between the midpalatine raphe and gingival margin of the first and second premolars. The pain of needle insertion, anesthetic solution deposition pain, and postinjection pain were recorded on a Heft-Parker VAS for the 2 AMSA injections. RESULTS For needle insertion, 38% of the subjects had moderate/severe pain with the Wand Plus((R)) and 34% moderate/severe pain with the conventional syringe, with no significant difference between techniques. There was a significant difference for solution deposition pain, with the conventional syringe causing more moderate/severe pain (42% conventional vs. 25% for the Wand Plus. Regarding postinjection pain, after numbness wore off there was no significant difference between the Wand Plus injection technique (0% moderate pain) and the conventional syringe technique (8% moderate pain). Postinjection, approximately 8% to 10% of the subjects experienced slight palatal swelling and 2% experienced temporary numbness. These problems resolved quickly and were considered minor. CONCLUSIONS The AMSA injection, using the Wand Plus, resulted in similar pain ratings for needle insertion as the conventional syringe but statistically lower pain ratings upon anesthetic solution deposition. However, the AMSA, using either the Wand Plus or a conventional syringe, has the potential to be a painful injection. We found the incidence of postinjection pain and sequelae was low with both techniques.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of a computerized anesthesia device with a traditional syringe in preschool children.

PURPOSE The purpose of this investigation was to evaluate the efficacy of a computerized injection device (Wand) on reducing pain behavior during injections with preschool-aged children. METHODS Subjects consisted of 40 patients between the ages of 2 and 5 requiring local anesthesia for dental restorations in the maxilla. Patients were randomly assigned to either the Wand or the traditional a...

متن کامل

The Wand vs. traditional injection: a comparison of pain related behaviors.

PURPOSE The purpose of this study was to evaluate the efficacy of a computerized anesthesia delivery system (e.g., Wand) compared to a traditional anesthesia administration, with respect to reducing disruptive pain related behavior during injections. METHODS Subjects consisted of 62 patients between the ages of 5 and 13 requiring local anesthesia for dental restorations in the maxilla. Patien...

متن کامل

Comparison of the Pain Levels of Computer-controlled and Conventional Anesthesia Techniques in Prosthodontic Treatment

OBJECTIVE The objective of this study was to compare the pain levels on opposite sides of the maxilla at needle insertion during delivery of local anesthetic solution and tooth preparation for both conventional and anterior middle superior alveolar (AMSA) technique with the Wand computer-controlled local anesthesia application. MATERIAL AND METHODS Pain scores of 16 patients were evaluated wi...

متن کامل

The wand versus traditional injection for mandibular nerve block in children and adolescents: perceived pain and time of onset.

PURPOSE The purpose of this study was to compare the perception of pain and time of onset in relation to mandibular alveolar nerve block administered by a computerized anesthesia delivery system (ie, The Wand) and a traditional anesthesia system (ie, the syringe). METHODS This study was conducted according to a split-mouth design, with both types of injections being given to all patients. Sub...

متن کامل

Comparison of the Pain Perception of Conventional and Computer-controlled Anesthesia Techniques for Extraction of Maxillary First Premolar

Introduction: Anterior middle superior alveolar (AMSA) block is a nerve block technique in conjunction with computer-controlled local anesthetic delivery (CCLAD) system. Anterior middle superior alveolar produces local anesthesia (LA) to the maxillary teeth from second premolar to the central incisor including the hard palate and corresponding soft-tissue of both buccal and palatal side, with s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Oral surgery, oral medicine, oral pathology, oral radiology, and endodontics

دوره 98 1  شماره 

صفحات  -

تاریخ انتشار 2004