Contact Force and Atrial Fibrillation Ablation.

نویسندگان

  • W Ullah
  • R J Schilling
  • T Wong
چکیده

Catheters able to measure the force and vector of contact between the catheter tip and myocardium are now available. Pre-clinical work has established that the degree of contact between the radiofrequency ablation catheter and myocardium correlates with the size of the delivered lesion. Excess contact is associated with steam pops and perforation. Catheter contact varies within the left atrium secondary to factors including respiration, location, atrial rhythm and the trans-septal catheter delivery technology used. Compared with procedures performed without contact force (CF)-sensing, the use of this technology has, in some studies, been found to improve complication rates, procedure and fluoroscopy times, and success rates. However, for each of these parameters there are also studies suggesting a lack of difference from the availability of CF data. Nevertheless, CF-sensing technology has been adopted as a standard of care in many institutions. It is likely that use of CF-sensing technology will allow for the optimization of each individual radiofrequency application to maximize efficacy and procedural safety. Recent work has attempted to define what these optimal targets should be, and approaches to do this include assessing for sites of pulmonary vein reconnection after ablation, or comparing the impedance response to ablation. Based on such work, it is apparent that factors including mean CF, force time integral (the area under the force-time curve) and contact stability are important determinants of ablation efficacy. Multicenter prospective randomized data are lacking in this field and required to define the CF parameters required to produce optimal ablation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Contact force technology in catheter ablation of atrial fibrillation

Catheter ablation of atrial fibrillation (AF) has an indisputable value in the treatment of patients with symptomatic drug refractory AF. Nowadays, special interest is paid to improve the efficacy and the safety of the procedure and new approaches allowing better understanding of the lesions creation and its control have been developed. A lot of factors including power and duration of energy de...

متن کامل

Effects Of Fast Pathway Ablation On The Concealment Zone And Electrophysiological Behavior Of AV-Node During Atrial Fibrillation.

Objectives: Dual pathways have a determinant role in the occurrence of atrio nodal tachyarrhythmia (AVNRT). The aim of present study is to determine the role of slow pathway (SP) in the concealment zone and protective role of AV node during atrial fibrillation (AF). Material &Methods: In 7 isolated nodal rabbit preparation zone of concealment and concealed conduction is quantified by Specif...

متن کامل

Possibility of contact force monitoring during catheter ablation of ventricular tachycardia

Nowadays, electroanatomical mapping system are widely used to clarify arrhythmic substrates and identify the target of ablation not only in patients with supraventricular tachycardia or atrial fibrillation but also ventricular tachycardia. To achieve good results in the procedure, it is important to obtain precise mapping information and to deliver adequate radiofrequency energy. Although it is...

متن کامل

Contact force mapping during catheter ablation for atrial fibrillation: procedural data and one-year follow-up

INTRODUCTION Pulmonary vein isolation (PVI) is the state-of-the-art treatment of atrial fibrillation (AF). Pulmonary vein reconnection is one of the main mechanisms of AF recurrence after ablation. Catheter-tissue contact is essential for effective ablation lesions. The aim of this study was to evaluate the impact of catheter contact monitoring during PVI on AF recurrence rate. MATERIAL AND M...

متن کامل

Target indices for clinical ablation in atrial fibrillation: insights from contact force, electrogram, and biophysical parameter analysis.

BACKGROUND In animal studies of radiofrequency ablation, lesion sizes plateau as the maximum lesion size is reached for an ablation. Lesion parameters are not available in clinical ablations, but preclinical work suggests that these correlate with impedance drop and electrogram attenuation. Characterization of the relationships between catheter contact force, ablation duration, and these surrog...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of atrial fibrillation

دوره 8 5  شماره 

صفحات  -

تاریخ انتشار 2016