A Comparison of intra-oral digital imaging modalities: Charged Couple Device versus Storage Phosphor Plate.

نویسندگان

  • A Anas
  • Jm Asaad
  • Ka Tarboush
چکیده

BACKGROUND This in vitro study was conducted to compare the accuracy of two digital image receptors in identifying the location of tip of a fine endodontic file and radiographic apex in mandibular posterior teeth. METHODS Fourteen human cadaver mandibles with retained molars were selected. These molars were prepared for access to the canals and an endodontic file #10 was introduced into the canal at one of the three random distances from the apex of the tooth. At each distance from the apex and at the apex of the tooth, images were made with two different image receptors; DenOptix storage phosphor plates and Gendex CCD sensor. Six raters viewed all the images for identification of the radiographic apex of the tooth and the tip of the endodontic file. Images were displayed randomly under standardized conditions. To assess intra-rater reliability, all the examiners viewed a subset of randomly selected images again after a time period of one week, inter rater reliability was also assessed. At the end of the study, teeth were extracted and the length of the canals measured to obtain a gold standard. RESULTS T-test revealed a significant main effect for the type of image, indicating that raters' error in identifying structures of interest was significantly higher for Denoptix storage phosphor plates. CONCLUSION The results of the study clearly reveal that Gnedex CCD produce most reliable images for Root Canal working length estimation when compared with Denoptix SPP.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Comparative Study of Diagnostic Accuracy of Cone Beam Computed Tomography and Intra Oral Digital Radiography Phosphor Storage Plates in Detecting Strip Perforation in Endodontically-Treated Teeth

Background and purpose: Perforation impairs the prognosis of endodontic treatments, so, timely and accurate diagnosis is important. For this purpose, various radiographic diagnostic tools have been studied to select the method that has the least complications and helps in making the most accurate diagnosis. This study aimed to compare the accuracy of cone beam computed tomography (CBCT) and int...

متن کامل

Comparison of Cone Beam Computerized Tomography and Phosphor Storage Plate in Detecting Artificial Buccal Recurrent Caries

Introduction Recurrent or secondary caries develops at the margin of restorations and causes restorative failure. We conducted this study to compare the performance of Phosphor Storage Plate (PSP) and Cone Beam Computed Tomography (CBCT) scan in detecting buccal recurrent caries under amalgam and composite resin restorations. Materials and Methods Class V cavities were prepared on the buccal...

متن کامل

Storage Phosphors for Medical Imaging

Computed radiography (CR) uses storage phosphor imaging plates for digital imaging. Absorbed X-ray energy is stored in crystal defects. In read-out the energy is set free as blue photons upon optical stimulation. In the 35 years of CR history, several storage phosphor families were investigated and developed. An explanation is given as to why some materials made it to the commercial stage, whil...

متن کامل

Evaluation of the Effect of Light and Scanning Time Delay on The Image Quality of Intra Oral Photostimulable Phosphor Plates

Background Nowadays, digital radiography is widely used in dental practice. One of the most common types is Photo Stimulated Phosphor Plate (PSP). Objective The aims of this experimental study were to evaluate the impacts of different combinations of storage conditions and varying delays in reading of digital images captured using PSPs. Methods Standardized images of a step wedges were obta...

متن کامل

مقایسه سنسورهای دیجیتالی Charge-Coupled Device با Photostimulable Phosphor Storage Plate در تشخیص شکستگی عمودی ریشه در دندان‌های اندو شده (مطالعه آزمایشگاهی)

  Objective: Vertical root fracture (VRF) is among the most common causes of endodontic treatment failures. This study aims to compare charge-coupled devices (CCD) and photostimulable phosphor plates (PSP) for detection of vertical root fractures in endodontically treated teeth.   Methods: In this diagnostic in vitro study, 40 maxillary anterior teeth were selected and after preparation and roo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International journal of health sciences

دوره 4 2  شماره 

صفحات  -

تاریخ انتشار 2010