Comparison of Calibration Methods for Tristimulus Colorimeters

نویسنده

  • James L. Gardner
چکیده

Uncertainties in source color measurements with a tristimulus colorimeter are estimated for calibration factors determined, based on a known source spectral distribution or on accurate measurements of the spectral responsivities of the colorimeter channels. Application is to the National Institute of Standards and Technology (NIST) colorimeter and an International Commission on Illumination (CIE) Illuminant A calibration. Detector-based calibration factors generally have lower uncertainties than source-based calibration factors. Uncertainties are also estimated for calculations of spectral mismatch factors. Where both spectral responsivities of the colorimeter channels and the spectral power distributions of the calibration and test sources are known, uncertainties are lowest if the colorimeter calibration factors are recalculated for the test source; this process also avoids correlations between the CIE Source A calibration factors and the spectral mismatch factors.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Spectral Response Based Calibration Method of Tristimulus Colorimeters

A new method is described to calibrate tristimulus colorimeters for high accuracy color measurements. Instead of traditional lamp standards, modern, high accuracy detector standards are suggested for calibration. After high accuracy absolute spectral response determination of the tristimulus receivers, color (spectral) correction and peak (amplitude) normalization can minimize uncertainties cau...

متن کامل

Four-Color Matrix Method for Correction of Tristimulus Colorimeters - Part 2

The Four-Color Method was developed to improve the accuracy of tristimulus colorimeters for measurements of color displays. It was verified that the method works well for cathode ray tubes (CRTs). The accuracy of this method has been studied further for spectral variations of displays including CRTs, liquid crystal displays (LCDs) and organic light emitting diode (OLED) displays. A theory for a...

متن کامل

Realization and application of a detector-based tristimulus color scale at the National Institute of Standards and Technology, USA

The recently introduced detector-based calibration method for tristimulus colorimeters has been realized. The NIST reference colorimeter has been calibrated for spectral irradiance responsivity with an uncertainty of 0.15 % (coverage factor k=2) resulting in a chromaticity uncertainty of 0.0004 (k=2) in the x and y chromaticity coordinates when a CIE Illuminant A source is measured. The color s...

متن کامل

Four-Color Matrix Method for Correction of Tristimulus Colorimeters

A new calibration method has been developed to improve the accuracy of chromaticity coordinates obtained from a tristimulus colorimeter for color displays. Matrix methods such as the one recommended by ASTM are well known for this purpose, but they may fail to work as expected due to experimental noise and errors. As these matrix methods are based on tristimulus values, the accuracy of the lumi...

متن کامل

Using adaptive matrix Correction Method for decreasing colour measuring systematic error in tristimulus colorimeters

In image taking colorimetry the tristimulus technique is still the practical viable method if the measuring time should be kept in limits. Due to the fact that the number of coloured glasses that are available to adjust the detector responsivity to the CIE colour matching functions (CMF) is limited and the number of the filters used in a channel can not be increased without limits to decrease t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 112  شماره 

صفحات  -

تاریخ انتشار 2007