Design and Study of Scintillator Crystals coupled to Silicon Photomultipliers for PET Application

نویسنده

  • Eric Oberla
چکیده

A relatively new photodetector, the silicon photomultiplier (SiPM), is well suited for PET applications. It has similar sensitivity and gain to the industry standard photomultiplier tube (PMT), but has advantages such as smaller size and insensitivity to magnetic field. These properties make SiPMs an active area of research in the PET field. I will study a simplified setup, comprised of two antiparallel SiPM/LSO coupled detectors using a Na-22 positron source. The coincidence timing and energy resolution will be determined for several crystal geometries and SiPM configurations. To simulate the experiment, GEANT4 code will be formulated to reproduce the results. Once the code successfully simulates this simple set-up, it can be extrapolated to simulate more complicated (and realistic) detector designs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Application of WLS strips for position determination in strip PET tomograph based on plastic scintillators

A method of determination of a gamma quantum absorption point in a plastic scintillator block using a matrix of wavelength-shifting (WLS) strips is proposed. Application of this method for improvement of position resolution in newly proposed PET detectors based on plastic scintillators is presented. The method enables to reduce parallax errors in reconstruction of images which occurs in the pre...

متن کامل

Evaluation of a SiPM array detector coupled to a LFS-3 pixellated scintillator for PET/MR applications.

Technological Educational Institute of Athens, Greece SiPM arrays are insensitive to magnetic fields and thus good candidates for hybrid PET/MR imaging systems. Moreover, due to their small size and flexibility can be used in dedicated small field of view small animal imaging detectors and especially in head PET/MR studies in mice. Co-doped LFS-3 scintillator crystals have higher light yield an...

متن کامل

PET-TOF study of Silicon Photomultipliers with DRS4 Readout

Our goal is to develop a system with 100 picosecond time resolution for time of flight positron emission tomography [PET-TOF] using silicon photomultipliers (SiPMs). We have obtained a coincidence time resolution of 188 ps FWHM with two LYSO crystals (3x3x15 mm) coupled to SiPMs and irradiated with Na source. The best time resolution was obtained with the signal trimmed by a clipping capacitanc...

متن کامل

BGO as a hybrid scintillator / Cherenkov radiator for cost-effective time-of-flight PET.

Due to detector developments in the last decade, the time-of-flight (TOF) method is now commonly used to improve the quality of positron emission tomography (PET) images. Clinical TOF-PET systems based on L(Y)SO:Ce crystals and silicon photomultipliers (SiPMs) with coincidence resolving times (CRT) between 325 ps and 400 ps FWHM have recently been developed. Before the introduction of L(Y)SO:Ce...

متن کامل

A novel, SiPM-array-based, monolithic scintillator detector for PET.

Silicon photomultipliers (SiPMs) are of great interest to positron emission tomography (PET), as they enable new detector geometries, for e.g., depth-of-interaction (DOI) determination, are MR compatible, and offer faster response and higher gain than other solid-state photosensors such as avalanche photodiodes. Here we present a novel detector design with DOI correction, in which a position-se...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009