Simple quantitative measurement of serum choriogonadotropin compared with immunoradiometric, immunoenzymometric, and chemiluminescent assays.

نویسندگان

  • R J Norman
  • T A Gilmore
  • J W McLoughlin
چکیده

We evaluated a new simplified quantitative method (Tandem Icon QSR; Hybritech) for choriogonadotropin (hCG), which could theoretically be performed in a ward or with outpatients. The method was compared with immunoradiometric (Bioclone Australia), chemiluminescent (Amerlite; Amersham), and immunoenzymometric assays (Stratus; Dade). We analyzed by each of the methods 104 serum samples from pregnant and nonpregnant patients. For quantitative hCG values indicative of pregnancy (greater than 25 int. units/L), excellent correlation was observed between the Tandem Icon method and the other standard laboratory assays (r = 0.995, 0.990, and 0.992, respectively). Occasional problems arose because of the instability of Tandem Icon QSR reagents at room temperature but this was resolved by storing the reagents at 4 degrees C. We conclude that this simplified quantitative method for hCG is reliable and suitable for use outside of the routine immunoassay laboratory.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The stratus automated immunofluorometric assay system: a modification for measuring urinary human choriogonadotropin.

The fluorometric enzyme immunoassays that can be run on the automated Stratus analyzer (American Dade, Miami, FL) are based on monoclonal antibodies coated to glass-fiber paper tabs. The available assays are specifically designed for quantification of analytes in plasma and serum, but not in urine. For example, eight urine samples with hCG concentrations <2.5 mt.units/L according to the Tandem-...

متن کامل

Immunoradiometric and luminescence immunoenzymometric assay of human thyrotropin from dried blood spots for screening of neonatal hypothyroidism.

Two monoclonal antibodies to thyrotropin prepared in our laboratory were employed for the development of two-site immunometric assays in two modifications for the estimation of human thyrotropin in dried blood spots designed for the screening of neonatal hypothyroidism. The immunoradiometric assay using the second antibody labelled with 125I is simple and fast (one incubation step lasting 2 h)....

متن کامل

Measurement of the free alpha subunit of human glycoprotein hormones by a monoclonal antibody-based immunoradiometric assay, and further exploration of antigenic sites on the choriogonadotropin molecule.

Three monoclonal antibodies were raised against the free alpha subunit of choriogonadotropin (hCG); each recognized a different antigenic site on the molecule. One (antibody 42) preferentially bound to the alpha subunit when it was coupled to the beta subunit as dimeric choriogonadotropin (hCG), thyrotropin (TSH), lutropin (LH), or follitropin (FSH). Antibody 71 showed some cross-reaction with ...

متن کامل

New separation method for monoclonal immunoradiometric assays and its application to assays for thyrotropin and human choriogonadotropin.

We describe a novel separation procedure for immunoradiometric assays involving monoclonal antibodies in which both radiolabeled and capture antibodies are used in solution, the capture antibody being labeled with fluorescein isothiocyanate (FITC). Separation is achieved by incubation with anti-FITC antibodies on magnetic particles. This technique enhances reaction kinetics relative to those of...

متن کامل

Testicular cancer secretes intact human choriogonadotropin (hCG) and its free beta-subunit: evidence that hCG (+hCG-beta) assays are the most reliable in diagnosis and follow-up.

Human choriogonadotropin (hCG) and free hCG-beta values for 934 serum samples from patients with seminomatous or nonseminomatous testicular cancer were measured by highly specific immunoradiometric assays (IRMAS). In non-seminoma samples, hCG and hCG-beta were highly correlated (r = 0.82, P less than 0.001). Of 112 "marker-positive" seminoma samples, only 46 (41.1%) showed both increased hCG an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 38 1  شماره 

صفحات  -

تاریخ انتشار 1992