Investigating the utility of clinical assessments to predict success with presbyopic contact lens correction.

نویسندگان

  • Ahmed Sivardeen
  • Deborah Laughton
  • James S Wolffsohn
چکیده

PURPOSE To determine the utility of a range of clinical and non-clinical indicators to aid the initial selection of the optimum presbyopic contact lens. In addition, to assess whether lens preference was influenced by the visual performance compared to the other designs trialled (intra-subject) or compared to participants who preferred other designs (inter-subject). METHODS A double-masked randomised crossover trial of Air Optix Aqua multifocal, PureVision 2 for Presbyopia, Acuvue OASYS for Presbyopia, Biofinity multifocal and monovision was conducted on 35 presbyopes (54.3±6.2years). Participant lifestyle, personality, pupil characteristics and aberrometry were assessed prior to lens fitting. After 4 weeks of wear, high and low contrast visual acuity (VA) under photopic and mesopic conditions, reading speed, Near Activity Visual Questionnaire (NAVQ) rating, subjective quality-of-vision scoring, defocus curves, stereopsis, halometry, aberrometry and ocular physiology were quantified. RESULTS After trialling all the lenses, preference was mixed (n=12 Biofinity, n=10 monovision, n=7 Purevision, n=4 Air Optix Aqua, n=2 Oasys). Lens preference was not dependent on personality (F=1.182, p=0.323) or the hours spent working at near (p=0.535) or intermediate (p=0.759) distances. No intersubject or strong intrasubject relationships emerged between lens preference and reading speed, NAVQ rating, halo size, aberrometry or ocular physiology (p>0.05). CONCLUSIONS Participant lifestyle and personality, ocular optics, contact lens visual performance and ocular physiology provided poor indicators of the preferred lens type after 4 weeks of wear. This is confounded by the wide range of task visual demands of presbyopes and the limited optical differences between current multifocal contact lens designs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A clinical decision support system for contact lens evaluation

Background: Contact lenses are transparent, thin plastic disks that cover the surface of the cornea. Appropriate lens prescription should be performed properly by an expert to provide better visual acuity and reduce side effects. The lens administration is a multi-stage, complex and time-consuming process involving many considerations. The purpose of this study was to develop a decision support...

متن کامل

Femtosecond Laser Restoration of Accommodation

The femtosecond laser has emerged as a revolutionary technology in the field of refractive surgery over the past decade, improving cornea-based procedures such as laser vision correction (eg, flap creation, SMILE) and laser-assisted keratoplasty. More recently, the femtosecond laser has been successfully applied to the crystalline lens to assist in cataract surgery. Presbyopia, which is defined...

متن کامل

Artificial pupil versus contralateral balanced contact lens fit for presbyopia correction.

PURPOSE To assess and compare the effects of contact lens-based artificial pupil design and contralateral balanced multifocal contact lens combination (CBMCLC) on visual performance. METHODS This randomized crossover study conducted at the University of Valencia, Spain included 38 presbyopic patients using an artificial pupil contact lens in the nondominant eye and a CBMCLC. After a month of ...

متن کامل

BCLA Pioneers Lecture - evidence basis for patient selection: how to predict contact lens success.

A prediction (Latin præ-, "before," and dicere, "to say") or forecast can be defined as “a statement about the way things will happen in the future, often but not always based on experience or knowledge. Although guaranteed information about the future is in many cases impossible, prediction is necessary to allow plans to be made about possible developments” (Wikipedia). Some predictions in the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Contact lens & anterior eye : the journal of the British Contact Lens Association

دوره 39 5  شماره 

صفحات  -

تاریخ انتشار 2016