Comparison of HRRT and HR+ Scanners

نویسندگان

  • Floris H.P. van Velden
  • Syahir Mansor
  • Daniëlle M.E. van Assema
  • Bart N.M. van Berckel
  • Femke E. Froklage
  • Shaonan Wang
  • Robert C. Schuit
  • Marie-Claude Asselin
  • Adriaan A. Lammertsma
  • Ronald Boellaard
  • Marc C. Huisman
چکیده

Purpose: To directly compare HRRT (high resolution brain) and HR+ (standard wholebody) PET only scanners for quantitative brain studies using three tracers with vastly different tracer distributions. Procedures: Healthy volunteers underwent successive scans on HR+ and HRRT scanners (in random order) using either (R)-[C]verapamil (n=6), [C]raclopride (n=7) or [C]flumazenil (n=7). For all tracers metabolite-corrected plasma input functions were generated. Results: After resolution matching, HRRT derived kinetic parameter values correlated well with those of HR+ for all tracers (intra-class correlation coefficients ≥0.78), having a good absolute interscanner test-retest variability (≤15%). However, systematic differences can be seen for HRRT derived kinetic parameter values (range: -13 to +15%). Conclusion: Quantification of kinetic parameters based on plasma input models leads to comparable results when spatial resolution between HRRT and HR+ data is matched. When using reference tissue models differences remain that are likely caused by differences in attenuation and scatter corrections and/or image reconstruction.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of 6 PET scanners, a simulation study [Persian]

Introduction: Due to the large number of PET systems available in the market, it is not very easy to decide about the scanner of choice. Conducting a research in order to compare all different PET scanners is very time consuming and expensive and practically impossible. However, such comparison may be conducted using PET simulators. In this study, the performance of 6 different PET scanne...

متن کامل

In vivo validation of reconstruction-based resolution recovery for human brain studies.

The aim of this study was to validate in vivo the accuracy of a reconstruction-based partial volume correction (PVC), which takes into account the point spread function of the imaging system. The NEMA NU2 Image Quality phantom and five healthy volunteers (using [(11)C]flumazenil) were scanned on both HR+ and high-resolution research tomograph (HRRT) scanners. HR+ data were reconstructed using n...

متن کامل

Assay for initiators and promoters of carcinogenesis based on attachment-independent survival of cells in aggregates.

A cell line (HRRT) derived from a hereditary renal rat tumor has been used in an assay for initiators and promoters of carcinogenesis based on attachment-independent survival in aggregates. Treatment with single noncytotoxic doses of the carcinogens urethan (1 mM), N-methyl-N-nitrosourea (30 microM), and benzo(a)pyrene (0.2 microM) for 1 hr did not affect survival of HRRT cells in the aggregate...

متن کامل

Performance comparison of four commercial GE discovery PET/CT scanners: A monte carlo study using GATE

  Combined PET/CT scanners now play a major role in medicine for in vivo imaging in oncology, cardiology, neurology, and psychiatry. As the performance of a scanner depends not only on the scintillating material but also on the scanner design, with regards to the advent of newer scanners, there is a need to optimize acquisition protocols as well as to compare scanner ...

متن کامل

Adapting MR-BrainPET scans for comparison with conventional PET: experiences with dynamic FET-PET in brain tumours

Institute of Neuroscience and Medicine (INM-3,-4,-5), Forschungszentrum Juelich, Juelich, Germany Imaging results from subsequent measurements (preclinical 3T MR-BrainPET, HR+) are compared. O-(2-[F]fluoroethyl)-L-tyrosine (FET) may exhibit non-uniform tracer uptake in gliomas. The aim was to analyse and adapt the physical properties of the scanners and study variations of biological tumour vol...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017