A Cadaveric, Biomechanical Analysis of Sternal Fixation Systems

ثبت نشده
چکیده

Rigid fixation of bony structures has been introduced and implemented as a means to improve stability and reduce motion. Tight fixation has been reported as an essential factor for successful healing1. A variety of devices including plates, intramedullary nails, pedicle screws and interbody fusion devices are used in orthopaedic, spinal and cranial facial procedures to provide rigid fixation. The sternum, however, remains one of the few bones that is not rigidly fixated. The purpose of this study was to compare the mechanical properties of wire cerclage with rigid fixation using plates and screws in human cadaveric sterna. Thirty-one sterna were tested in lateral distraction, rostro-caudal shear, and anterior/posterior shear using a pneumatic test system to determine strength and stiffness. Rigid fixation with plates was shown to exhibit superior mechanical properties compared to wire cerclage. When tested in lateral distraction, the stiffness of the plates was more than 400% greater than peristernal wires (p<0.05). Similarly, the yield load (560N vs. 397N) was also significantly better in sterna that were rigidly fixated. Rigid fixation of the sternum following a median sternotomy with SternaLock plates results in superior stability, stiffness and strength when compared to peristernal wires. Introduction Immobilization supports bony union. This was recognized thousands of years ago by the Egyptians, who splinted fractures6. A clinical study demonstrated higher fusion rates when rigid fixation or metal to metal devices were used as compared to laminar fixation with hooks or wires6. A variety of rigid fixation systems have been developed and utilized in orthopedic applications, including intramedullary nails, spinal fusion devices, external fixators, and cranial and maxillofacial plates. These systems give the surgeon the necessary tools to stabilize the bone, allowing for bone remodeling and healing to progress. Sternal stability and union following a sternotomy is an important step in returning the patient to normal activity. One factor in the development of sternal wound infections is bony instability after sternotomy1. Wire cerclage has historically been used to reduce the sternum. Sternal separation and dehiscence following closure with wire cerclage has been reported to occur at a rate of 0.3–8%. These complications are often costly, and have been linked to mortality rates of 10-40%1,5. To date, few studies have been published comparing the mechanical properties of rigid fixation with sternal plates to the traditional method of wire cerclage. An in vitro study* demonstrated that rigid plates provide significantly more stable fixation that wires2. A separate study in baboons* demonstrated rigid fixation resulted in earlier union with primary osseous healing, suggesting greater inherent stability3. Objective To compare the mechanical properties (stiffness, yield load, and ultimate load) between wire cerclage and rigid sternal fixation using SternaLock plates in cadaveric sterna. Methods Thirty-one cadaveric sterna were used in this analysis. Each sternum sample was accompanied by CT scans, and the age and gender of the donor. Each sternum was divided along the midline and closed with peristernal wires or SternaLock plates, consistent with a sternotomy procedure. A cardiothoracic surgeon assisted in the wiring and plating. Group A (n=15; Fig.1a) consisted of divided sterna closed with three trans-sternal wires at the manubrium and five peristernal wires along the body of the sterna. Group B (n=16; Fig. 1b) used two “X” plates on the sternum body A Cadaveric, Biomechanical Analysis of Sternal Fixation Systems 1 Rigid Fixation with SternaLock® System Results in Superior Stability Compared to Wire Cerclage

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biomechanical analysis of the FlatWire Figure 8 sternal fixation device.

OBJECTIVE To determine whether the FlatWire Figure 8 sternal fixation device (Penn United, USA) is mechanically superior to the current standard in sternotomy closure. DESCRIPTION Unstable sternal closure using traditional steel-wire cerclage can increase postoperative pain, bony cut-through and wound dehiscence. The authors present the Figure 8 sternal fixation device to minimize these compl...

متن کامل

A new technical approach for sternal closure with suture anchors (Dogan technique).

OBJECTIVES Various methods for sternal approximation have been described previously. Some patients undergoing these procedures are at risk for sternal dehiscence and mediastinitis. We used a different method, with a suture anchor system, for median sternotomy closure as an alternate technique in patients with a high risk of postoperative sternal dehiscence and sternal nonunion. MATERIAL AND M...

متن کامل

The Stabilising Effect of the Anterior Oblique Ligament to Prevent Directional Subluxation at the Trapeziometacarpal Joint of the Thumb: A Biomechanical Cadaveric Study

Background: The trapeziometacarpal joint (TMCJ) is inherently unstable, relying on ligament restraint to preventsubluxation. Subluxation of the thumb in a dorsoradial direction is often observed in clinical practice, either after acuteligament injury or more commonly with osteoarthritis (OA). This subluxation follows loss of function of trapeziometacarpalligaments that stabilise this joint, res...

متن کامل

Comparison of the biomechanical properties of a ventral cervical intervertebral anchored fusion device with locking plate fixation applied to cadaveric canine cervical spines.

OBJECTIVE To evaluate fixation properties of a new intervertebral anchored fusion device and compare these with ventral locking plate fixation. STUDY DESIGN In vitro biomechanical evaluation. ANIMALS Cadaveric canine C4-C7 cervical spines (n = 9). METHODS Cervical spines were nondestructively loaded with pure moments in a nonconstraining testing apparatus to induce flexion/extension while...

متن کامل

Biomechanical analysis of blade plate versus locking plate fixation for a proximal humerus fracture: comparison using cadaveric and synthetic humeri.

OBJECTIVE To compare the mechanical stability of a fixed-angle blade plate with that of a locking plate in a cadaveric proximal humerus fracture-fixation model subjected to cyclic loading. A secondary objective was to evaluate whether the use of synthetic humerus specimens would replicate significant differences found during cadaveric tests. DESIGN Mechanical evaluation of constructs in bendi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011