Placement of thoracolumbar pedicle screws using three-dimensional image guidance: experience in a large patient cohort.
نویسندگان
چکیده
OBJECT The goal of this study was to analyze the placement accuracy and complications of thoracolumbar pedicle screws (PSs) inserted using 3D image guidance in a large patient cohort. METHODS The authors reviewed the charts of 220 consecutive patients undergoing posterior spinal fusion using 3D image guidance for instrumentation placement. A total of 1084 thoracolumbar PSs were placed using either the BrainLAB Vector Vision (BrainLAB, Inc.) or Medtronic StealthStation Treon (Medtronic, Inc.) image guidance systems. Postoperative CT scanning was performed in 184 patients, allowing for 951 screws to be graded by an independent radiologist for bone breach. All complications resulting from instrumentation placement were noted. Using the intraoperative planning function of the image-guided system, the largest diameter screw possible in each particular case was placed. The screw diameter of instrumentation placed into the L3-S1 levels was noted. RESULTS No vascular or visceral complications occurred as a result of screw placement. Two nerve root injuries occurred in 1084 screws placed, resulting in a 0.2% per screw incidence and a 0.9% patient incidence of nerve root injury. Neither nerve root injury was associated with a motor deficit. The breach rate was 7.5%. Grade 1 and minor anterolateral "tip out" breaches accounted for 90% of the total breaches. Patients undergoing revision surgery accounted for 46% of the patients in this study. Accordingly, 154 screws placed through previous fusion mass could be evaluated using postoperative CT scanning. The breach rate in this specific cohort was 7.8%. A total of 765 PSs were placed into the L3-S1 levels in this study; 546 (71%) of these screws were > or = 7.5 mm in diameter. No statistical difference in breach rate was noted in PSs placed through revision spinal levels versus nonrevision spinal levels (p = 0.499). Additionally, no increase in breach rate was noted with placement of 7.5-mm-diameter screws. CONCLUSIONS Three-dimensional image guidance is a useful adjunct to placement of spinal instrumentation. The complication rate in this study was low, and accurate placement of instrumentation was achieved despite the high percentage of revision surgery cases in our patient population. Additionally, because active fluoroscopy was not used for instrumentation placement, there was minimal to no radiation exposure to the surgeon or operating room staff.
منابع مشابه
Cost-Effectiveness of Image-Guided Spine Surgery
OBJECTIVE To determine if image-guided spine surgery is cost effective. METHODS A prospective case series of the first 100 patients undergoing thoracolumbar pedicle screw instrumentation under image-guidance was compared to a retrospective control group of the last 100 patients who underwent screw placement prior to the use of image-guidance. The image-guidance system was NaviVision (Vector V...
متن کامل"Free-hand" technique for thoracolumbar pedicle screw instrumentation: critical appraisal of current "state-of-art".
Pedicle screws are widely used for instrumentation of the thoracolumbar spine. The anatomic studies performed in the last two decades, detailing the complex morphometry and three-dimensional anatomy of the thoracolumbar pedicles, have enabled the emergence of the so-called "free-hand" technique of pedicle screw placement based exclusively on anatomical parameters. However, in the thoracic spine...
متن کاملComparing Accuracy of Cervical Pedicle Screw Placement between a Guidance System and Manual Manipulation: A Cadaver Study
BACKGROUND The aim of this study was to compare the accuracy of cervical pedicle screw placement between a three-dimensional guidance system and manual manipulation. MATERIAL AND METHODS Eighteen adult cadavers were randomized into group A (n=9) and group B (n=9). Ninety pedicle screws were placed into the C3-C7 under the guidance of a three-dimensional locator in group A, and 90 screws were ...
متن کاملNavigation on the Thoracic and Lumbar Spine
tem since their introduction in clinical application in 1995 [1, 26]. The navigation at the spine with the help of a CT-based navigation, or the navigation using a 2D data set, from a conventional image converter, have become established methods at centers working with navigation. Numerous publications proof that these systems can be utilized in clinical practice, and in most cases contribute t...
متن کاملPedicle Screw Placement in the Thoracolumbar Spine Using a Novel, Simple, Safe, and Effective Guide-Pin : A Computerized Tomography Analysis
OBJECTIVE To improve pedicle screw placement accuracy with minimal radiation and low cost, we developed specially designed K-wire with a marker. To evaluate the accuracy of thoracolumbar pedicle screws placed using the novel guide-pin and portable X-rays. METHODS Observational cohort study with computerized tomography (CT) analysis of in vivo and in vitro pedicle screw placement. Postoperativ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of neurosurgery. Spine
دوره 10 1 شماره
صفحات -
تاریخ انتشار 2009