Towards model-based adaptive optics optical coherence tomography.
نویسندگان
چکیده
The transfer function for optical wavefront aberrations in single-mode fiber based optical coherence tomography is determined. The loss in measured OCT signal due to optical wavefront aberrations is quantified using Fresnel propagation and the calculation of overlap integrals. A distinction is made between a model for a mirror and a scattering medium model. The model predictions are validated with measurements on a mirror and a scattering medium obtained with an adaptive optics optical coherence tomography setup. Furthermore, a one-step defocus correction, based on a single A-scan measurement, is derived from the model and verified. Finally, the pseudo-convex structure of the optical coherence tomography transfer function is validated with the convergence of a hill climbing algorithm. The implications of this model for wavefront sensorless aberration correction are discussed.
منابع مشابه
Refractive index tomography of turbid media by bifocal optical coherence refractometry.
We demonstrate tomographic imaging of the refractive index of turbid media using bifocal optical coherence refractometry (BOCR). The technique, which is a variant of optical coherence tomography, is based on the measurement of the optical pathlength difference between two foci simultaneously present in a medium of interest. We describe a new method to axially shift the bifocal optical pathlengt...
متن کاملAdaptive Optics Optical Coherence Tomography for in Vivo Retinal Imaging
Optical coherence tomography (OCT) is a non-invasive micrometer-resolution volumetric imaging modality that has been employed in diverse applications. In this thesis, we first describe a GPU accelerated program to perform FDOCT data processing and real time 3D volumetric rendering. The real time visualization of volumetric images provided by the GPU acceleration was essential to the rest of the...
متن کاملAdaptive ranging for optical coherence tomography.
At present, optical coherence tomography systems have a limited imaging depth or axial scan range, making diagnosis of large diameter arterial vessels and hollow organs difficult. Adaptive ranging is a feedback technique where image data is utilized to adjust the coherence gate offset and range. In this paper, we demonstrate an adaptive optical coherence tomography system with a 7.0 mm range. B...
متن کاملAdaptive optics optical coherence tomography for in vivo mouse retinal imaging.
Small animal models of retinal diseases are important to vision research, and noninvasive high resolution in vivo rodent retinal imaging is becoming an increasingly important tool used in this field. We present a custom Fourier domain optical coherence tomography (FD-OCT) instrument for high resolution imaging of mouse retina. In order to overcome aberrations in the mouse eye, we incorporated a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Optics express
دوره 22 26 شماره
صفحات -
تاریخ انتشار 2014