A case of ostial stenosis with the PAS-Port proximal anastomosis system in off-pump coronary artery bypass grafting.

نویسندگان

  • Hironori Izutani
  • Masao Yoshitatsu
  • Jun Kawamoto
  • Keijiro Katayama
چکیده

The use of an automatic aortic connector device for proximal saphenous vein graft anastomoses eliminates the need for aortic clamping during off-pump coronary artery bypass grafting and may reduce the incidence of stroke in the elderly and in patients with severe aortic atherosclerosis. The PAS-Port proximal anastomotic system is a recently developed sutureless automatic saphenous vein graft anastomosis device. We used the system in thirteen patients. Overall handling, feasibility and safety of the device were satisfactory in our limited experience. However, one patient developed severe ostial and proximal graft stenosis in four months postoperative angiogram.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

[Reoperative off-pump coronary revascularization via left thoracotomy using the PAS-Port system to the descending thoracic aorta: report of a case].

We performed redo-off-pump coronary artery bypass grafting( OPCAB) via a left thoracotomy using the PAS-Port system for proximal vein graft anastomoses in a patient with posterolateral myocardial ischemia. The patient was a 76-year-old man who had undergone coronary artery bypass grafting (CABG)[ left internal thoracic artery( LITA)-left anterior descending artery( LAD), saphenous vein graft(SV...

متن کامل

Use of skeletonized radial artery graft with the PAS-Port proximal anastomotic device.

PURPOSE We report our initial experience with the PAS-Port proximal anastomosis system (Cardica Inc, Redwood City, CA) using full-skeletonized radial artery (RA) in patients requiring off-pump coronary artery bypass grafting. DESCRIPTION The PAS-Port system (Cardica Inc) was used in 25 patients undergoing off-pump coronary artery bypass surgery. All patients received at least one RA graft usi...

متن کامل

Clinical outcome of the PAS-Port® proximal anastomosis system in off-pump coronary artery bypass grafting in 201 patients.

AIM The PAS-Port® Proximal Anastomosis System (Cardica, Inc, Redwood City, CA, USA) has been used worldwide since March 2003. The objective of the present study was to evaluate the clinical outcome of the PAS-Port® Proximal Anastomosis System. METHODS All the patients who underwent off-pump coronary artery bypass grafting in the Catharina Hospital Eindhoven between August 2006 and April 2010 ...

متن کامل

Study of coronary artery bypass using the PAS-Port device: assessment by multidetector computed tomography.

OBJECTIVE The use of automatic anastomotic devices in coronary artery bypass grafting surgery is associated with lower patency rates in comparison to conventional anastomosis methods. This is thought to be caused by graft curvature occurring after closing of the chest wall. METHODS We evaluated 39 grafts in 28 patients who underwent off-pump coronary artery bypass surgery using the PAS-Port. ...

متن کامل

Avoidance of Dialysis in an End-Stage Renal Disease Patient Status-post Off-pump Coronary Artery Bypass Grafting

Certain benefits are clearly associated with the use of off-pump coronary artery bypass grafting (CABG) as compared with the on-pump CABG. The superiority is more evident in patients with multiple co morbidities including renal failure.We reviewed the medical records of a 67-year-old male with a past medical history that was significant for multiple cardiovascular diseases and new-onset end-sta...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Interactive cardiovascular and thoracic surgery

دوره 4 4  شماره 

صفحات  -

تاریخ انتشار 2005