Wind Tunnel Analysis of the Airflow through Insect-Proof Screens and Comparison of Their Effect When Installed in a Mediterranean Greenhouse

نویسندگان

  • Alejandro López
  • Francisco D. Molina-Aiz
  • Diego L. Valera
  • Araceli Peña
چکیده

The present work studies the effect of three insect-proof screens with different geometrical and aerodynamic characteristics on the air velocity and temperature inside a Mediterranean multi-span greenhouse with three roof vents and without crops, divided into two independent sectors. First, the insect-proof screens were characterised geometrically by analysing digital images and testing in a low velocity wind tunnel. The wind tunnel tests gave screen discharge coefficient values of Cd,φ of 0.207 for screen 1 (10 × 20 threads·cm(-2); porosity φ = 35.0%), 0.151 for screen 2 (13 × 30 threads·cm(-2); φ = 26.3%) and 0.325 for screen 3 (10 × 20 threads·cm(-2); porosity φ = 36.0%), at an air velocity of 0.25 m·s(-1). Secondly, when screens were installed in the greenhouse, we observed a statistical proportionality between the discharge coefficient at the openings and the air velocity ui measured in the centre of the greenhouse, ui = 0.856 Cd + 0.062 (R² = 0.68 and p-value = 0.012). The inside-outside temperature difference ΔTio diminishes when the inside velocity increases following the statistically significant relationship ΔTio = (-135.85 + 57.88/ui)(0.5) (R² = 0.85 and p-value = 0.0011). Different thread diameters and tension affects the screen thickness, and means that similar porosities may well be associated with very different aerodynamic characteristics. Screens must be characterised by a theoretical function Cd,φ = [(2eμ/Kpρ)·(1/us) + (2eY/Kp(0.5))](-0.5) that relates the discharge coefficient of the screen Cd,φ with the air velocity us. This relationship depends on the three parameters that define the aerodynamic behaviour of porous medium: permeability Kp, inertial factor Y and screen thickness e (and on air temperature that determine its density ρ and viscosity μ). However, for a determined temperature of air, the pressure drop-velocity relationship can be characterised only with two parameters: ΔP = aus² + bus.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An Auto-Tuning PI Control System for an Open-Circuit Low-Speed Wind Tunnel Designed for Greenhouse Technology

Wind tunnels are a key experimental tool for the analysis of airflow parameters in many fields of application. Despite their great potential impact on agricultural research, few contributions have dealt with the development of automatic control systems for wind tunnels in the field of greenhouse technology. The objective of this paper is to present an automatic control system that provides prec...

متن کامل

EXPERIMENTAL INVESTIGATION OF EFFECTS OF WALL POROSITY AND SUCTION ON THE FLOW QUALITY IN A TRANSONIC WIND TUNNEL

A trisonic wind tunnel has been modified to improve its flow quality when operating at transonic speeds through perforated walls and side suctions. The usefulness of such a perforated wall, already known, is reduction of the blockage effect as well as the shock elimination. Two types of perforated walls have been used in this investigation. The first wall had a porosity of about 22% and the hol...

متن کامل

Natural Ventilation: Analysis of Indoor Airflow in an Assumed Cubic Building with Opposite Openings by CFD Investigations

The natural ventilation is an easy way to exchange the indoor polluted warm air with outdoor fresh air. The wind power injects outdoor fresh air into the building. A good indoor air current and subsequently a proper exhaust depend on the openings’ conditions and their situations. A serious architectural question is under what conditions of the openings the wind-cross ventilation can be effectiv...

متن کامل

Experimental and numerical study of natural ventilation in four-sided wind tower traps

In the past, wind towers were applied as the main architectural part of building construction in the desert areas of Iran. These almost high structures were used as cooling load suppliers at residential buildings. In the present study, the effect of symmetric four-sided wind tower in flow induction to the bottom space has been analysed by using a wind tunnel and numerical simulations. In the nu...

متن کامل

Sonic Anemometry to Measure Natural Ventilation in Greenhouses

The present work has developed a methodology for studying natural ventilation in Mediterranean greenhouses by means of sonic anemometry. In addition, specific calculation programmes have been designed to enable processing and analysis of the data recorded during the experiments. Sonic anemometry allows us to study the direction of the airflow at all the greenhouse vents. Knowing through which v...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Sensors

دوره 16 5  شماره 

صفحات  -

تاریخ انتشار 2016