Anisotropic permeability in deterministic lateral displacement arrays.

نویسندگان

  • Rohan Vernekar
  • Timm Krüger
  • Kevin Loutherback
  • Keith Morton
  • David W Inglis
چکیده

We uncover anisotropic permeability in microfluidic deterministic lateral displacement (DLD) arrays. A DLD array can achieve high-resolution bimodal size-based separation of microparticles, including bioparticles, such as cells. For an application with a given separation size, correct device operation requires that the flow remains at a fixed angle to the obstacle array. We demonstrate via experiments and lattice-Boltzmann simulations that subtle array design features cause anisotropic permeability. Anisotropic permeability indicates the microfluidic array's intrinsic tendency to induce an undesired lateral pressure gradient. This can cause an inclined flow and therefore local changes in the critical separation size. Thus, particle trajectories can become unpredictable and the device useless for the desired separation task. Anisotropy becomes severe for arrays with unequal axial and lateral gaps between obstacle posts and highly asymmetric post shapes. Furthermore, of the two equivalent array layouts employed with the DLD, the rotated-square layout does not display intrinsic anisotropy. We therefore recommend this layout over the easier-to-implement parallelogram layout. We provide additional guidelines for avoiding adverse effects of anisotropy on the DLD.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improved performance of deterministic lateral displacement arrays with triangular posts

Deterministic lateral displacement arrays have shown great promise for size-based particle analysis and purification in medicine and biology. Here, we demonstrate that the use of an array of triangular rather than circular posts significantly enhances the performance of these devices by reducing clogging, lowering hydrostatic pressure requirements, and increasing the range of displacement chara...

متن کامل

Stochastic Analysis of Seepage through Natural Alluvial Deposits Considering Mechanical Anisotropy

The soil is a heterogeneous and anisotropic medium. Hydraulic conductivity, an intrinsic property of natural alluvial deposits varies both deterministically and randomly in space and has different values in various directions. In the present study, the permeability of natural deposits and its influence on the seepage flow through a natural alluvial deposit is studied. The 2D Finite Difference c...

متن کامل

Separation of deformable particles in deterministic lateral displacement devices.

Using numerical simulations, we study the separation of deformable bodies, such as capsules, vesicles, and cells, in deterministic lateral displacement devices, also known as bump arrays. These arrays comprise regular rows of obstacles such as micropillars whose arrangements are shifted between adjacent rows by a fixed amount. We show that, in addition to the zigzag and laterally displaced traj...

متن کامل

Scaling deterministic lateral displacement arrays for high throughput and dilution-free enrichment of leukocytes

A disposable device for fractionation of blood into its components that is simple to operate and provides throughput of greater than 1 mL min−1 is highly sought after in medical diagnostics and therapies. This paper describes a device with parallel deterministic lateral displacement devices for enrichment of leukocytes from blood. We show capture of 98% and approximately ten-fold enrichment of ...

متن کامل

Inhibition of clot formation in deterministic lateral displacement arrays for processing large volumes of blood for rare cell capture.

Microfluidic deterministic lateral displacement (DLD) arrays have been applied for fractionation and analysis of cells in quantities of ~100 μL of blood, with processing of larger quantities limited by clogging in the chip. In this paper, we (i) demonstrate that this clogging phenomenon is due to conventional platelet-driven clot formation, (ii) identify and inhibit the two dominant biological ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Lab on a chip

دوره 17 19  شماره 

صفحات  -

تاریخ انتشار 2017