Thermal Resistance Anastomosis Device for the Percutaneous Creation of Arteriovenous Fistulae for Hemodialysis.
نویسندگان
چکیده
PURPOSE To evaluate the safety and efficacy of arteriovenous fistula (AVF) creation with a thermal resistance anastomosis device (TRAD). MATERIALS AND METHODS From January 2014 to March 2015, 26 patients underwent ultrasound (US)-guided percutaneous creation of proximal radial artery-to-perforating vein AVFs with a TRAD that uses heat and pressure to create a fused anastomosis. Primary endpoints were fistula creation, patent fistula by Doppler US, two-needle dialysis at the prescribed rate, and device-related complications. RESULTS Technical success rate of fistula creation was 88% (23 of 26). Procedure time averaged 18.4 minutes (range, 5-34 min), and 96% of anastomoses (22 of 23) were fused. At 6 weeks, 87% of AVFs (20 of 23) were patent, 61% (14 of 23) had 400-mL/min brachial artery flow, 1 patient was receiving dialysis, 2 fistulae had thrombosed, and 1 patient had died unrelated to the procedure. Eighty percent (16 of 20), 70% (14 of 20), and 60% (12 of 20) of patients were receiving dialysis at 3, 6, and 12 months; 4 patients died, 3 fistulae failed, and one patient was lost to follow-up. Overall, 87% of AVFs (20 of 23) had an additional procedure at a mean of 56 days (range, 0-239 d), including balloon dilation in 43% (n = 10), brachial vein embolization in 26% (n = 6), basilic vein ligation in 17% (n = 4), venous transposition in 30% (n = 7), and valvulotomy in 4% (n = 1). There were no major complications related to the device. CONCLUSIONS Percutaneous AVFs created with a TRAD met the safety endpoints of this study. Midterm follow-up demonstrated intact anastomoses and fistulae suitable for dialysis.
منابع مشابه
Percutaneous transluminal angioplasty in the treatment of stenosis of arteriovenous fistulae for hemodialysis
BACKGROUND Thrombosis following stenosis of arteriovenous fistulae resulting in the loss of vascular access for hemodialysis is an important complication in patients with chronic renal failure. Percutaneous transluminal angioplasty is being used more frequently in the treatment of stenosis aiming at increasing the patency of arteriovenous fistulae. OBJECTIVE To evaluate the primary patency of...
متن کاملMaturation of arteriovenous fistula: Analysis of key factors
The growing proportion of individuals suffering from chronic kidney disease has considerable repercussions for both kidney specialists and primary care. Progressive and permanent renal failure is most frequently treated with hemodialysis. The efficiency of hemodialysis treatment relies on the functional status of vascular access. Determining the type of vascular access has prime significance fo...
متن کاملPrimary and secondary patency rates and complications of upper extremity arteriovenous fistulae created for hemodialysis.
The types of fistulae used and their complication rates are important for the hemodialysis patients. We aimed to compare retrospectively the primary and secondary patency rates and complications of upper extremity arteriovenous fistulae. Between 1984 and 2005, a total of 1,233 upper extremity arteriovenous fistulae were created in 920 patients. The mean age was 42 +/- 21 years. The fistulae wer...
متن کاملPercutaneous transluminal angioplasty for stenosis of arteriovenous fistulae: a review of local experience.
The stenosis and subsequent thrombosis of the arteriovenous fistulae may lead to a loss of vascular access sites; this a major problem in chronic haemodialysis patients. Percutaneous transluminal angioplasty has been a popular way of correcting such lesions in recent years. We have reviewed patients who underwent this operation from 1993 to 1996 at the Queen Mary Hospital. Among 11 patients who...
متن کاملParadoxical embolism after declotting of hemodialysis fistulae/grafts in patients with patent foramen ovale.
BACKGROUND AND OBJECTIVES The safety of percutaneous endovascular declotting procedures for thrombosed hemodialysis fistulae/grafts is well described in the general population; however, its safety in the presence of a patent foramen ovale (PFO) is not known. The objective of this study is to assess the incidence of symptomatic paradoxical embolic events associated with declotting procedure of t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of vascular and interventional radiology : JVIR
دوره 28 3 شماره
صفحات -
تاریخ انتشار 2017