Theoretical analysis of tablet hardness prediction using chemoinformetric near-infrared spectroscopy.

نویسندگان

  • Hideaki Tanabe
  • Kuniko Otsuka
  • Makoto Otsuka
چکیده

In order to clarify the theoretical basis of the variability in the measurement of tablet hardness by compression pressure, NIR spectroscopic methods were used to predict tablet hardness of the formulations. Tablets (200 mg, 8 mm in diameter) consisting of berberine chloride, lactose, and potato starch were formed at various compression pressures (59, 78, 98, 127, 195 MPa). The hardness and the distribution of micropores were measured. The reflectance NIR spectra of various compressed tablets were used as a calibration set to establish a calibration model to predict tablet hardness by principal component regression (PCR) analysis. The distribution of micropores was shifted to a smaller pore size with increasing compression pressure. The total pore volume of tablets decreased as the compression pressure increased. The hardness increased as the compression pressure increased. The hardness could be predicted using a calibration model consisting of 7 principal components (PCs) obtained by PCR. The relationship between the predicted and the actual hardness values exhibited a straight line, an R(2) of 0.925. In order to understand the theoretical analysis (scientific background) of calibration models used to evaluate tablet hardness, the standard error of cross validation (SEV) values, the loading vectors of each PC and the regression vector were investigated. The result obtained with the calibration models for hardness suggested that the regression vector might involve physical and chemical factors. In contrast, the porosity could be predicted using a calibration model composed of 2 PCs. The relationship between the predicted and the actual total pore volume showed a straight line with R(2) = 0.801. The regression vector of the total pore volume might be due to physical factors.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Contribution to the Application of Near-Infrared Spectroscopy for Tablet Analysis: Metformin Hydrochloride Tablets Case Study

Near-infrared spectroscopy (NIRS) is a rapid and nondestructive analytical method. The use of near-infrared spectroscopy in the pharmaceutical industry has been rapidly increasing over the past decade, with particular interest in the analysis of solid dosage forms, such as tablets and capsules [1]. This article describes use of NIR spectroscopy to determine of content the active pharmaceutical ...

متن کامل

Prediction of Freshness Quality and Phosphate Residue of White Shrimp Products Using Near-Infrared Spectroscopy

 Background: The manufacturing of frozen shrimp is an important industry for the economy of Thailand. The objective of this study was to use Near-Infrared (NIR) spectroscopy to determine the freshness quality, including Total Volatile Basic Nitrogen (TVB-N) and Water Holding Capacity (WHC) of white shrimp (whole and chopped shrimp) and phosphate residues of shrimp. Methods: Sixty white shrimp ...

متن کامل

Potential of Near-Infrared Reflectance Spectroscopy (NIRS) to Predict Nutrient Composition of Bromus tomentellus

Determination of forage quality of available species is one of the fundamentalfactors for the management of rangelands. Near-Infrared Reflectance Spectroscopy (NIRS)was used to analysis the Nitrogen (N), Acid Detergent Fiber (ADF), Dry MatterDigestibility (DMD) and Metabolizable Energy (ME) content of three phenological stages(vegetative, flowering and seeding) of Bromus tomentellus samples in ...

متن کامل

Near-Infrared-Spectroscopic Investigations of Solid Pharmaceutical Formulations

In this study near-infrared (NIR) transmission and diffuse reflection spectra of tablets with two different pharmaceutical active substances in variable concentrations were recorded. The purpose of these tests was to correlate the spectra with the content of active ingredient, hardness and moisture content in order to implement a fast, non-destructive quality control of solid drug formulations ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 23 7  شماره 

صفحات  -

تاریخ انتشار 2007